2
Puttingtheboilerintooperation
CONDENSATIONWALLGASBOILERS
Beforefirstputtingintooperationitisnecessarytotakefollowingsteps:
Procedureofthefirstboilerburning:
:
Theboilermustbeputintooperationbyaserviceworkertrainedbyproducer!
1.Checkwhethertheheatingsystemisfilledwithwaterandtheboilerisdeareated
properly.
2.Makesureifallthevalvesareopen.
3.Openthegasvalveinstalledpriortotheboilerandtestthesealingofthegas
pipingintheboiler.
1.Plugthefeedingflexintothe230V/50Hzsocket.
Testthesocketwithanotherappliance.
2.Settheheatingtemperatureandswitcharoomthermostat(if
connected)on.
3.Putthemodeswitchtothepositionwinter.
4.Checktheproperoperationofallthethermostatsandcontrolelements.
5.Settheboileroutputbytherequestofheatedplace.
ATTACKKT,KST-
TheboilerissetbytheproducertonaturalgasG20,inletgaspressure20mbar,
ortoLPGgasG31,inletgaspressure37mbar.
Beforeinstallationandputtingtheboilerintooperationitisnecessarytoget
acquaintedwiththeinstructionforuse.
TheboilerisofIIcathegory.
TheKTboilerisofB,C,C,C,C,Ctype.
2H3P
331333435383