8
Puttingtheboilerintooperation:
Settingupthetemperatureofheatingandhotwater
Firstputtingtheboilerintooperationcanbedoneonlybyatrainedauthorizedservice
partneroftheATTACKcompany.Whenoperatingtheboiler,ausercanmanipulateonly
withcontrolelementsandafillingvalve.Thisvalveisnotapartoftheboiler,buttheheating
circuitmustbeequippedwithit.Whenstartingtheoperation,itisnecessaryforallthe
connectinglines(connectionofheatingsystem,ofnaturalgasandcondensateoutlet)tobe
sealedandtestedbyrevisions.Forfillingtheheatingcircuititisrecommendedtousesoft,
filteredrainwater.Waterhardnessintheheatingcircuitcannotbehigherthan3mval/l.When
puttingtheboilerintooperation,checkwhetheralltheclosingvalvesareopen.Plugthe
cableintothesocket.
Afterplugginginthedisplayofthecontrolfrontboardshowstheinformationonthe
softwaretypeoftheproductfor2seconds.
Ifthereisnorequestforheatingandnobreakdownregistered,thedisplayshowscurrent
outlettemperatureofheatingwater.TheboilerisintheSTAND-BYmode,readyfor
operation.Ifthepressureofheatingwaterislowerthan0,8bar,E37errorisindicated.
Currentpressureofheatingwaterinthecircuitcanbedisplayedintheinformationmode(see
thepartInformationmode).Ifthedisplayedvalueofpressureislowerthan0,8bar,itis
necessarytoincreasethesystemto11,5barusingthefillingvalve.Afterincreasingthe
pressure,thevalveistobeclosed.Thefillingvalveshouldbeequippedbyanon-returnflap
valvetopreventcontaminationofdrinkwaterbywaterfromtheboiler.Thiscouldhappenif
thefillingvalvewasnotclosedproperlyandpressureintheheatingcircuitwashigherthan
pressureofwaterinpiping.
Theboilercanbesetintowintermodebythebutton__________.Operationoftheboilerin
thewintermodeissignalizedbyLEDdiodeoverthebutton__________,whichisnot
shining.Inthismodetheboilerisreadyforheatingintheheatingsystem.
IftherequestforheatingcomesfromthethermostatorfromcontactsoftheOPENTHERM
communication,theboilerisputintooperationwithinafewseconds.Thedisplayshows
currenttemperatureofheatingwater.Asmallredlightintherightlowercornerofthedisplay
signalsthattheboilerhasstartedcorrectlyandthemainburnerisoperating.
TheLEDdiodeatthesymbol_________isshining,signalizingtherequestfromthe
thermostatforheating.Whentherequestisattheend,thediodegoesout.
TheATTACKKTboilerisalsoequippedwithanti-cyclingfunction.Aftertherequestfor
heating,anti-cyclingtimeisactivatedduringwhichtheboilerwillnotrespondtotherequest
forheating.Afterthistimetheboilerisrestarted.Anti-cyclingtimeissignalledbyflickering
oftheLEDdiodeatthesymbol_________.
Ifthereisarequesttoheatwater,theLEDdiodeonthefrontboardatthesymbol_______
lightsupandcurrenttemperatureofhotwatercomingoutoftheboilerisdisplayed.
Thetemperatureofheatingwatercanbechangedbythebuttons+/-atthesymbol
_________.Withthehelpofthebutton+therequiredtemperatureisrisenandwiththe
helpofthebuttonthetemperatureislowered.Thetemperatureisshowedonthedisplayof
theboiler.Therequiredtemperatureisconfirmedandsavedintothememoryautomaticlyif
in5secondsthevalueisnotchanged.
Thetemperatureofhotwatercanbealsochangedwiththebuttons+/-,butatthesymbol
________,whilethetemperatureisbeingdisplayed.Therequiredtemperatureissavedifthe
temperatureisnotchangedin5seconds.