EasyManua.ls Logo

German pool SGV-5221 - Technical Specifications

German pool SGV-5221
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P.49
Display Cause
Solution
E01
Chamber high temperature protection
(temperature in the chamber is higher than
security setting)
Stop working, open oven door for 8-10
minutes, and restart the appli-ance.
E02
Evaporator high temperature protection
(temperature in evaporator is higher than
security setting)
Stop working, wait for 8-10 minutes, and
restart the appliance.
E03
Chamber low temperature protection (the unit
works for 3 minutes under 35°C)
1. Check if drain switch in the chamber
is closed, if not, close it and reboot the
appliance.
2. Contact customer service & re-pair centre.
E04
Evaporator low temperature protection (the
unit works for 3 minutes under 35°C)
Contact customer service & repair centre.
E05
Sensor connection failure (open circuit of
chamber or
evaporator sensor)
Contact customer service & repair centre.
E06
Malfunction of sensor (short circuit of chamber
or
evaporator sensor)
Contact customer service & repair centre.
Alarm Troubleshooting
Care & Maintenance
Specication
Model No.
SGV-5221
Voltage/Frequency 220-240V/50Hz
Rated Power 2,100W
Product Dimension
(H×W×D)
455mm×595mm×550mm
Cavity Size
(H×W×D)
Approx. 225mm×470mm×410mm
Tank Cavity
1.3L
Net weight 32 Kg
Specications are subject to change without prior notice.
If there is any inconsistency or ambiguity between the English version and the
Chinese version, the English version shall prevail.
Refer to www.germanpool.com for the most up-to-date version of the Operating
Instructions.