Slimdrive SL NT/SL NT-FR
5
Safety
3.3 Safety conscious working
à Secure workplace against unauthorised entry.
à Watch pivoting range of long parts.
à Never carry out work with a high safety risk (e.g. installing the drive, cover or door leaf) while alone.
à Secure the cover/drive panels against falling.
à Use only cables prescribed in the cable plan provided. Lay shields in accordance with the wiring diagram.
à Secure loose, internal drive cables with cable ties.
à Before working on the electrical system:
à Disconnect the drive from the 230 V mains and check to ensure that it is not supplied with power.
à Disconnect the control from the 24 V battery.
à Note that if an uninterruptible power supply (UPS) is used, the system will still be supplied with power
despite the fact that the power supply is disconnected.
à Always use insulated wire-end ferrules for wire cores.
à Attach safety stickers to glass door leaves.
à Danger of injury with opened drive. Hair, clothing, cables, etc. can be drawn in by rotating parts!
à Danger of injury through unsecured crushing, impact, drawing-in or shearing spots!
à Danger of injury by broken glass!
à Danger of injury due to sharp edges in the drive!
à Danger of injury during installation through freely moving parts!
3.4 Inspection of the installed system
Measures for security and prevention of pinching, impact, shearing or drawing-in spots:
à Check the functioning of safety sensors and movement detectors.
à The detection eld of the movement detector in the direction of the emergency exit must cover the opening
width x 1.5 m in front of the door.
à The movement detector in the direction of the emergency exit (see AutSchR) must detect people moving
faster than 0.1 m/s.
à Check protective earth connection to all metal parts that can be touched.
à Perform a safety analysis (risk analysis).
3.5 Environmentally conscious working
à When disposing of the door system, separate the dierent materials and have them recycled.
à Do not dispose of batteries and storage cells with household waste.
à Comply with the statutory regulations when disposing of the door system and the batteries/rechargeable
batteries.