2.2 INSTALLATION
2.0 INSTALLATION
100k
CN1
E L N
SMA0411
470R
0.22uF
PC814
OPS v.1.1
PC814
1
L N
E E N L SL E N SL
2
3 4 5 6 7 8 9 10
Mains
Boiler Boilerpump
11
NC N SL1 SL2 E E N SL
12
13 14 15 16 17 18
DHW pump
Valve / htg pump
20
N L HW HTG E E L N SL
21
22 23 24 25 26 27 28
Room thermostat
Clock / programmer
29
+
-
T1 T2 - + T3 - +
30
31 32 33 34 35 36 37
PSC
FS
SAC
Sw1
Sw2
1
2 3 4 5
L N E
L N E
L N E
BR
GY BL BLK
B W R R
GY
BL
BK
Boiler
Pump
Heating
Pump
DHW
Pump
BL
BR
GY
GY
BL
BR
BR
BR
BR
GY
BL
BLK
Store Sensor
PHE Return Sensor
DWH Sensor
R
R
W
B
Wiring Key
R
BR
BL
GY
BLK
Red
Brown
Blue
Green/Yellow
Black
Cable Cleat
Flat twin and earth
PVC cable
10mm
2
Feed cable supplied with 3 metres available
externally to connect to local isolator
Programmable
Room Stat.
Remove link when
Room Stat installed
Teleswitch PCB
Winter - 0
Summer - 1
BR
BL
Note : 30A fuse carriers F1 and F2
are fitted with 25A fuses (30 25LC)
30A
30A
F1 F2
AC30 AC30
LIVE
Dual Heating
Element
13
14
14
23
23
24
24
13
Store Overheat
Thermostat
Boiler Overheat
Thermostat
R
R
R
R
R
R
R
R
R
R
R
R
R
R
L L
NN
BL
BL
BL
BL
BL
BL
BLK
BR
BR
BR
BR
GY
GY
GY
GY
ISSUE 10
DATE : DECEMBER 2002
APPROVED
PR1
PR2
A1
A1
A2