14
GB
7 Shutting down
7.1 Emptying & Cleaning >> Figures
Danger to health due to escaping spraying agents! Pay attention to the
safety instructions in this manual. Observe applicable laws and the specifications of the
agent manufacturers when disposing of residual quantities.
Initially vent the standing container fully by pulling on the piston-type pressure gauge with the
built-in safety valve “l” and completely releasing the air.
Now unscrew the pump carefully, at first only a few turns of the thread in a counter-clockwise
direction so that any residual compressed air in the container can escape. Only now unscrew and
remove the pump completely.
Do NOT pour the residual quantity into the sink, but pour it through the filling hole into a suit-
able canister.
7.2 Maintenance >>
Figures
Observe the national regulations concerning occupational safety which apply to the place of
operation as well as the applicable national regulations for operations.
Only use original GLORIA spare parts for repairs. (see GLORIA spare parts shop https://shop.glo-
riagarten.de).
Repairs must only be carried out by a GLORIA service point.
Regularly coat the seals with GLORIA silicone grease.
Further accessories can be found at www.gloriagarten.de
7.3 Storage >>
Figures
/
You must therefore store the device and the spraying agents out of the
reach of children.
Empty and clean the device as in Chapter 7.1.
8 Problems with the device
9 Disposal
The emptied and unusable device must be recycled at a collection point, separated according to the materials.
Dispose of packaging materials that are no longer required according to the locally applicable regulations.
10
EU Declaration of Conformity
EU Declaration of Conformity for a module as defined by Article 4, section 3 of the Directive on pres-
sure equipment 2014/68/EU // GLORIA Haus- und Gartengete GmbH; rmannsbusch 7; D-58456 Witten
confirms that the pressurised components of the pressure sprayer prima 5 Plus comply with Directive
2014/68/EU, article 4, paragraph 3.
Witten, 01.12.2018
Ludger Strunk (Head of Development and Design)
24
19
27
25
28
24
WARNING
Fault Cause Remedy
Device is leaking at the
screw connection
Hose loose
Tighten coupling nut and carry
out pressure test with water
Spray pattern of
nozzle not OK
Nozzle partially blocked
Filter in quick closure valve
contaminated
Clean filter or nozzle
Pump does not build
up any pressure
O-ring on piston is
worn
Replace O-ring