Appendix
0020229560_00 Betacom 3 Installation and maintenance instructions 33
Dia-
gnostics
code
Parameter
Values
Unit Increment, select, explanation
Default set-
ting
User-spe-
cific setting
Min. Max.
d.45 Value for the base point
of the heating curve
15 30 1 20 Adjustable
d.47 Outside temperature Current value Not
adjustable
d.50 Correction of the min-
imum fan speed
0 3000 rpm 1
Fan speed = Display value x 10
600 Adjustable
d.51 Correction of the max-
imum fan speed
-2500 0 rpm 1
Fan speed = Display value x 10
-1000 Adjustable
d.58 Solar circuit reheating 0 3 0 = Boiler's Legionella protection
function deactivated
3 = Hot water activated (min.
target value 60 °C)
0 Adjustable
d.60 Number of blocks by the
temperature limiter
Current value Not
adjustable
d.61 Number of unsuccessful
ignitions
Current value Not
adjustable
d.62 Night set-back 0 30 1 0 Adjustable
d.64 Average burner ignition
time
Current value s Not
adjustable
d.65 Maximum burner ignition
time
Current value s Not
adjustable
d.66 Activation of the warm
start function for hot wa-
ter
off = Function deactivated
on = Function activated
1 Adjustable
d.67 Remaining burner anti-
cycling time (setting un-
der d.02)
Current value min Not
adjustable
d.68 Number of unsuccessful
ignitions at 1st attempt
Current value Not
adjustable
d.69 Number of unsuccessful
ignitions at 2nd attempt
Current value Not
adjustable
d.70 Operation of the diverter
valve
0 2 0 = Normal operating mode
(DHW and heating mode)
1 = Mid-position (parallel opera-
tion)
2 = Permanent setting: Heating
mode
0 Adjustable
d.71 Maximum heating flow
set target temperature
45 80 1 Section
"Technical
data"
Adjustable
d.73 Correction of the hot wa-
ter warm start temperat-
ure
-15 5 1 0 Adjustable
d.75 Maximum cylinder re-
heating time
20 90 min 1 45 Adjustable
d.77 Max. cylinder reheating kW 1
Section "Technical data"
Adjustable
d.80 Running time in heating
mode
Current value h Running time = Display value x
100
Not
adjustable
d.81 Running time in hot wa-
ter handling mode
Current value h Running time = Display value x
100
Not
adjustable
d.82 Number of burner igni-
tions in heating mode
Current value Number of ignitions = Display
value x 100
Not
adjustable
d.83 Number of burner igni-
tions in hot water hand-
ling mode
Current value Number of ignitions = Display
value x 100
Not
adjustable