34 Installation and maintenance instructions Betacom 3 0020229560_00
Dia-
gnostics
code
Parameter
Values
Unit Increment, select, explanation
Default set-
ting
User-spe-
cific setting
Min. Max.
d.84 Maintenance in 0 3000 h Number of hours = Display value
x 10
300 Not
adjustable
d.85 Increase in the min. out-
put (heating and hot wa-
ter handling mode)
kW 1
Section "Technical data"
Adjustable
d.88 Flow rate limit value
for ignition in hot water
handling mode
0 1 0 = 1.7 l/min (no delay)
1 = 3.7 l/min (2 s delay)
0 Adjustable
d.90 Status of the eBUS room
thermostat
Current value off = Not connected
on = Connected
Not
adjustable
d.91 Status DCF77 Current value Not
adjustable
d.93 Setting the product code 0 99 1 Adjustable
d.94 Delete fault list 0 1 off = No
on = Yes
Adjustable
d.95 Software versions 1 = Main PCB
2 = Interface PCB
Adjustable
d.96 Default setting (reset) 0 = No
1 = Yes
Adjustable
d.128 Heating minimum target
value
10 75 1 10 Adjustable
d.129 Minimum hot water tar-
get value
35
(com-
bination
unit)
45
(pure
boiler)
60 1 35
(combination
unit)
45 (pure
boiler)
Adjustable
C Status codes Overview
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Status code Meaning
Displays in heating mode
S.0 Heating mode: No requirement
S.01 Heating mode: Advance fan operation
S.02 Heating mode: Pump pre-run
S.03 Heating mode: Burner ignition
S.04 Heating mode: Burner on
S.05 Heating mode: Pump/fan overrun
S.06 Heating mode: Fan overrun
S.07 Heating mode: Pump overrun
S.08 Heating mode: Temporary shutdown after heating procedure
Displays in hot water handling mode
S.10 Hot water handling mode: Requirement
S.11 Hot water handling mode: Advance fan operation
S.13 Hot water handling mode: Burner ignition
S.14 DHW mode: Burner on
S.15 DHW mode: Pump/fan overrun
S.16 DHW mode: Fan overrun

Table of Contents