2 Product description
10 Operating and installation instructions MiSet 0020288229_00
MENU → SETTINGS
→ Installation con-
figuration
Functions (→ Installation configuration menu item)
→ Screed drying Activate the Screed drying profile function for freshly laid screed in
accordance with the construction regulations.
The system control regulates the flow temperature independently of
the outdoor temperature. Setting screed drying (→ Installation config-
uration menu item)
→ Change code
→ Language, time, display
→ Language:
→ Date: After the power is switched off, the date is retained for approx. 30
minutes.
→ Time: After the power is switched off, the time is retained for approx. 30
minutes.
→ Display brightness:
→ Daylight saving
time:
→ Automatic
→ Manual
The change takes place:
– On the last weekend in March at 02:00 (daylight saving time)
– On the last weekend in October at 03:00 (standard time)
→ Offset
→ Room temperat-
ure: K
Comparison of the temperature difference between the measured
value in the system control and the value for a reference thermometer
in the living room.
→ Outdoor temper-
ature: K
Comparison of the temperature difference between the measured
value in the outdoor temperature sensor and the value for a reference
thermometer in the living room.
→ Factory settings The system control resets all of the settings to the factory settings and
calls up the installation assistant.
Only the competent person can call up the installation assistant.
2.10.4 Installation configuration menu item
MENU → SETTINGS → Installer level → Installation configuration
→ Installation
→ Water pressure: bar
→ eBUS components List of eBUS components and their software versions
→ Adaptive heat curve: Automatic fine adjustment of the heat curve. Prerequisite:
– The suitable heat curve for the building is set in the Heat
curve: function.
– The correct zone is assigned to the system control or the
remote control in the Zone assignment: function.
– Expanded is selected in the Room temp. mod.: function.
→ Control:
R.temp.contr
It is controlled via the room temperature.