11 Inspection and maintenance
22 Installation and maintenance instructions SUSTAIN ..s 0020200967_00
11.2 Procuring spare parts
The original components of the product were also certified
as part of the declaration of conformity. If you do not use
certified Glow-worm original spare parts for maintenance
or repair work, this voids the conformity of the product. We
therefore strongly recommend that you install Glow-worm
original spare parts. Information about available Glow-worm
original spare parts is available by contacting the contact
address provided on the reverse of this document.
If you require spare parts for maintenance or repair work,
use only Glow-worm original spare parts.
11.3 Removing the gas-air mixture unit
Note
The gas-air mixture unit consists of three main
components:
Ventilator
Gas valve,
Burner cover
1. Switch off the product via the main switch.
2. Close the gas isolator cock.
3. Remove the front casing. ( Page 10)
B
A
1
C
2
4. Push the clip (1) upwards.
5. Remove the flue pipe (2).
3
4
5
A
B
6. Remove the air intake pipe (3).
7. Remove the plugs from the gas valve (4) and from the
fan (5).
A
C
D
B
6
8. Remove the gas-air mixture unit (6).
7
7
8
9. Remove the burner seals (7) and the burner (8).
10. Check the burner and the heat exchanger for damage
and dirt.
11. If necessary, clean or replace the components accord-
ing to the following sections.
12. Install the two new burner seals.

Table of Contents