4.4 Dimensions
96
121
34
123
185
390
123
170
702
150
1 2 3
4
1 Heating flow
2 Gas connection
3 Heating return
4 Flue pipe connection
4.5 Minimum clearances
CC
A
B
D
Minimum clearance
A 150 mm
B 150 mm
C 5 mm
D 600 mm
4.6 Clearance from combustible components
It is not necessary to maintain a clearance between the
product and components made of combustible materials.
4.7 Using the installation template
Use the installation template to ascertain the locations at
which you need to drill holes and make breakthroughs.
4.8 Wall-mounting the product
Note
If you are using the rear air/flue gas connection,
install the flue pipe before you wall-mount the
product.
B
A
1. Check whether the wall has sufficient load-bearing ca-
pacity to bear the operational weight of the product.
2. Check if the supplied fixing material may be used for
the wall.
Conditions: The load-bearing capacity of the wall is sufficient, The fixing
material may be used for the wall
Wall-mount the product as described.