19.3.1 Expansion vessel
B
C
D
E
A
3
2
1
4
2
1
Key
1 Connector
2 Expansion vessel
3 Upper support bracket
4 Retainingscrew
5 Gasket
Drain the boiler heating circuit as described in the appropriate
chapter "Draining".
Remove the two screws (4).
Undo the connector (1) at the base of the vessel.
Remove upper support bracket (3).
Remove the expansion vessel (2).
Fit a new gasket between the expansion vessel and
connector.
Rell, vent and pressurise the boiler.