10. RV-C INSTANCE NUMBER
10.1 RV-C INSTANCE NUMBER IDENTIFICATION
The RV-C instance of an individual controller can be identied by the 5 LEDs on the controller shown below.
10.1 CHANGING THE RV-C INSTANCE NUMBER
The instance of the solar controller on the RV-C network can be congured using the SET button and LEDs. Up to 5
unique instances are supported. To change the instance follow these steps:
1. Hold the SET button down for approximately 3 seconds until one of the LEDs starts ashing.
2. Press the SET button to change instance until the LED for the desired instance is ashing.
3. Press and hold the SET button for approximately 3 seconds to lock in the setting.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Go Power 10 AMP RVC-MPPT and is the answer not in the manual?

Go Power 10 AMP RVC-MPPT Specifications

General IconGeneral
Battery Voltage Range8V – 16V
Battery TypeLead Acid (AGM, GEL, Flooded), LiFePO4
Max Charge Current10A
Max Panel Input Voltage100Voc
Max PV Power Input200W
Conversion Efficiency≤98%
MPPT Tracking Efficiency>99%
No-Load Loss<10mA
GroundingNegative
Max Wire Gauge8 AWG
Operating Temperature-35 to 45°C
Storage Temperature-35 to 75°C
Humidity95% N.C.
Water Ingress ProtectionIP32
Altitude< 3000m
ProtectionSolar/battery reverse polarity Solar/battery over voltage Solar/battery short circuit Over temperature
Weight and Dimensions IconWeight and Dimensions
Dimensions (H x W x D)3.35” x 6.1” x 1.57”
Weight0.67lbs (300g)