EasyManua.ls Logo

Go Power GP-175 User Manual

Go Power GP-175
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Go PGo P
Go PGo P
Go P
oo
oo
o
ww
ww
w
er! Maner! Man
er! Maner! Man
er! Man
ualual
ualual
ual
GP-175 Inverter
Go Power! Electric Inc.
PO Box 6033
Victoria, BC V8P 5L4
Tel: 866-247-6527
Fax: 866-607-6527
Email: info@gpelectric.com
8. Maintenance
Very little maintenance is required to keep your inverter operating properly. You should
clean the exterior of the unit periodically with a dry cloth to prevent accumulation of
dust and dirt. At the same time, tighten the screws on the DC input terminals.
9. Warranty
We warrant this product against defects in materials and workmanship for a period of 12
months from the date of purchase and will repair or replace any defective Go Power!
Inverter when directly returned, postage prepaid, to the manufacturer. This warranty will
be considered void if the unit has suffered any obvious physical damage or alteration
either internally or externally, and does not cover damage arising from improper use such
as plugging the unit into an unsuitable power sources, attempting to operate products
with excessive power consumption requirements, reverse polarity, or use in unsuitable
climates.
This is the only warranty and the company makes no other warranties, express or
implied, including warranties of merchantability and fitness for a particular purpose.
Repair or replacement are your sole remedies and shall not be liable for damages,
whether direct, incidental, special or consequential, even though caused by negligence
or other fault.
Go Power! Modified Sine Wave Inverter
Owner’s Manual
8
Problem and Symptoms
Low AC output voltage
95-105 VAC.
No output voltage and LED
indicator is red.
No output voltage, LED
indicator is red.
No output voltage, no lights.
Low battery alarm on all the
time, LED indicator is red.
Possible Cause
Using standard voltmeter.
Overload.
High input voltage.
Car lighter fuse, Inverter
lighter cable fuse or
interconnect cable fuse
open.
Low input voltage.
Poor DC wiring, poor
battery condition.
Solution
Use true RMS averaging meter.
Reduce load.
Make sure that inverter is
connected to 12 V battery.
Check regulation of charging
system.
Check and replace.
Make sure that inverter is
connected to 12 V battery.
Check regulation of charging
system.
Recharge battery. Use proper
cable and make solid connec-
tions. Use new battery.
as short as possible and twist them together with about 2 to 3
twists per foot. This minimizes radiated interference from the
cables.
7.2 Troubleshooting guide
Question and Answer IconNeed help?

Do you have a question about the Go Power GP-175 and is the answer not in the manual?

Go Power GP-175 Specifications

General IconGeneral
ModelGP-175
Output Power175W
Input Voltage12V DC
Output Voltage120V AC
WaveformModified Sine Wave
Efficiency90%
TypeInverter
Protection FeaturesOverload, Short Circuit

Summary

Troubleshooting Guide

Low AC Output Voltage Diagnosis

Troubleshoot low AC output voltage (95-105 VAC) by using a true RMS averaging meter.

No Output Voltage / Red LED Issues

Diagnose no output voltage with red LED indicating overload, high input voltage, or open fuses.

Low Battery Alarm / Red LED

Address low battery alarm or red LED by checking input voltage, wiring, and battery condition.

Maintenance Procedures

Routine Cleaning and Tightening

Periodically clean the unit with a dry cloth and tighten DC input terminals for proper operation.

Warranty and Limitations

Product Warranty Coverage

Warrants against defects for 12 months; repair/replace. Void if damaged by misuse or alteration.

Warranty Exclusions

Excludes damage from improper use, reverse polarity, or unsuitable climates. No other implied warranties.

Operating Limits and Troubleshooting

Overload Protection

Fault LED indicates overload or short circuit. Correct fault and restart the inverter.

Input Voltage Range

Operates 10-15V. Protects battery below 10V and inverter above 15V.

Audio System Buzz

Buzzing in stereos due to modified sine wave. Use higher quality power supply.

Television Interference

Minimize TV interference by optimizing signal, distance, and load management.

Product Introduction and Specifications

Introduction to Go Power! Inverters

Provides mobile AC power for RVs, boats, and remote homes. Match inverter to load requirements.

GP-175 Inverter Specifications

Details output, voltage, input, protection, dimensions, and weight for the GP-175 model.

Features and Installation

GP-175 Front View Controls

Identifies AC outlets, ON/OFF switch, Power LED, and Fault LED on the inverter's front.

GP-175 Rear View Ports

Locates ventilation port for airflow and DC input plug for power connection.

Installation Location Requirements

Install in dry, cool, ventilated, and safe locations, within 10 feet of batteries.

Hook-up and Testing Guidelines

Connect DC input plug to lighter receptacle and test with loads. Note car lighter fuse rating.