The Goldair Classic Heat/Light/Vent is a fixed bathroom appliance designed for installation into the ceiling, providing a combination of heating, lighting, and ventilation functions. It is available in two models: GHL255W and GHL455W, differing primarily in their heat lamp configuration (2-lamp or 4-lamp units). This product is intended for household use in rooms requiring direct radiant heating and circulated airflow, such as bathrooms, ensuites, and laundries.
Function Description
The device integrates three essential bathroom functions into a single ceiling-mounted unit:
- Heating: The primary heating function is provided by 275W heat lamps. The 2-lamp model (GHL255W) offers two heat lamps, while the 4-lamp model (GHL455W) provides four, allowing for varying levels of radiant heat. These lamps are designed to provide immediate warmth, making the bathroom more comfortable, especially during colder periods.
- Lighting: A central 9W R63 LED globe provides general illumination for the room. This light can be operated independently of the heating and ventilation functions.
- Ventilation: An integrated exhaust fan is designed to extract air from the room, helping to remove steam, odors, and excess moisture. This is crucial for maintaining air quality and preventing mold and mildew growth in damp environments. The fan's efficiency relies on adequate replacement air entering the room, typically through a gap under the door or a slightly open window. The unit incorporates a thermal cut-out feature that will automatically activate the fan if the internal temperature exceeds 80°C, ensuring safe operation.
Usage Features
The Goldair Classic Heat/Light/Vent is operated via a wall switch plate, which is included with the unit. The switch plate features separate controls for each function, allowing users to customize their bathroom environment:
- Light Control: A dedicated "LIGHT" switch turns the central LED globe on and off.
- Fan Control: A "FAN" switch activates and deactivates the ventilation fan. It is recommended to always turn the fan on when using the heat lamps to minimize heat build-up within the unit.
- Heat Control: The heat lamps are controlled by one or two "HEAT" switches, depending on the model. For the 2-lamp unit, one "HEAT" switch will turn both lamps on or off. For the 4-lamp unit, pressing one "HEAT" switch will activate two heat lamps, while pressing both "HEAT" switches will turn on all four heat lamps, providing greater heating intensity.
For optimal ventilation, it is important to ensure sufficient airflow into the room. The fan should operate without a change in speed or sound when the bathroom door is opened or closed, indicating adequate air replacement.
Maintenance Features
Regular maintenance is essential to ensure the longevity and efficient operation of the Goldair Classic Heat/Light/Vent.
- Cleaning Frequency: The globes and front fascia should be wiped regularly. The exhaust fan and ducting kit also require periodic cleaning.
- Safety First: Always switch off the power to the unit at the mains before commencing any cleaning or maintenance tasks. Allow the globes to cool down completely before handling them.
- Exterior Cleaning: The globes and the front fascia can be cleaned with a soft cloth dampened with water or a neutral detergent.
- Fan and Ducting Cleaning: The exhaust fan should be cleaned of dust and dirt using a dry or wet cloth. It is also important to clean the exhaust ducting kit to ensure that the airways are clear and free from any obstructions that could impede airflow.
- Lamp Replacement: Heat lamps and light bulbs are consumable items. When replacing them, unscrew the old lamps anticlockwise and screw in the new ones firmly to ensure good electrical contact. Care should be taken not to overtighten the lamps, as this can damage the lamp holders or the lamps themselves. The heat lamps and light bulbs supplied with the unit are test bulbs and are not covered under the product warranty.
Installation Considerations
Installation of this product must be carried out by a registered electrician in accordance with AS/NZS 3000 and any local regulations, especially concerning mounting in damp areas. The unit is designed for installation in flat ceilings with a minimum height of 2.1 meters from the floor and should not be installed directly above shower or bath recesses or enclosures. Specific clearance requirements must be adhered to: at least 250mm away from vertical walls, a minimum of 100mm above the top of the unit, and 50mm clearance between the sides of the unit and joists, walls, or insulation. The appliance must not be covered with insulating material or similar materials. The wiring diagram provided in the manual details the electrical connections, emphasizing the need for a 'permanent active' connection and a double pole disconnecting device in the circuit.