SAFETY PRECAUTIONS
- "HZ" input for calls from apartment front door Up to 8 monitors/ apartments with push
button "HZ" activated at the same time (with system and monitors in standby).
. Important:
- Hands-free monitor.
- .User menu
- 50mA/12V ).Output auxiliary call repeater (max. dc
.
- Monitor .with simple installation (non-polarised 2 wires bus)
- .Installer menu
- .Image and communication settings menu
.
.User
.
.
.
- Push buttons for door release 1 and 2.
- 4,3 olo r ." TFT c u screen
- for access and selection of menu function.Function push buttons
- eds.Notification l
- .Configuration switches to assign the address and to define whether the monitor is master or slave
.
.
.
- before installing or making modifications to the device.Always disconnect the power supply
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
.
- The wiring must run at least 40 cm. away from any other wiring.
.
- The fitting and handling of these devices must be carried out by .authorised personnel
- Do not overtighten the screws on the connector.
-Always follow the instructions contained in this manual.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
CHARACTERISTICS
SYSTEM OPERATION
*
( )
*
( )
3
DESCRIP MONITORTION
Monitor address (code) setup:
*
( )
*
( )
*
( )
INSTALA MONITORTION OF THE
*
( )
Building / Villa (Nexa Door Panel)
Dip1 Dip5:- Sets the monitor address (addresses to 3 ).1 2
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
.
Master Slave 1 Slave 2 Slave 3
.Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable
ends. Deactivate it only in intermediate monitors.
.
Dip6-Dip7: These dene whether the monitor is master or slave. Each apartment must have one master monitor,
and only one.
*
( )
ENEN
ART /G2+4 MONITOR
- the button below sh wn onTo establish communication, press off-the-hook icon o the screen. Door
panel LED will .will turn off and the led turn on
.
- or , button below the displayedTo open door of the door panel on the
screen 3
press the corresponding icon
during the call or communication processes: one press will activate the lock release for
seconds and LED will also turn on for seconds. If vocal synthesis is enabled, a 'Door
open' message will be indicated on the door panel.
door panel 3 is
.
- mmunication the button below shown on the screen
is door panel
Co will last for 90 seconds or until on-the-hook icon
pressed. When communication ends, LED will turn off and the system will become free. If
vocal synthesis is enabled, a 'Communication is finished' message will indicate that the call is over.
- 4 .Detailed operation of the monitorand configuration , see "TART /G2+" user manual
.
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that the call
is being made and LED will turn on. If vocal synthesis is enabled, a 'Call is in progress'
message appears indicating that a call is being made.At this moment, the apartment's monitors receive
the call. If another apartment is called by mistake, press the button for the correct apartment and the first
call will be cancelled.
door panel
.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon displayed on the screen will blink green. To view the
image from slave monitors 2 or 3, press . If the
call is not answered within 45 seconds, LED will turn off and the system will become free.
one of the buttons of the monitor to display the image
door panel
.
1
2
*
1 2 3
ON
4 5 6 7 8 1 2 3
ON
4 5 6 7 8 1 2 3
ON
4 5 6 7 8 1 2 3
ON
4 5 6 7 8
1 2 3
ON
Example: 0+ 0+4+0+16= 20
Switch number:
Value when ON 1 2 4 8 16:
1 2 3 4 5
Table of values
4 5 6 7 8
Important:
4/ 3monitor .with V.0 and later
Apartment 1 (Dip1 to ON & Dip2-Dip5 to OFF)
ART G2+
Important: Apartment 32 (Dip1 - Dip5 to OFF).
Villa (Soul Door Panel)
Dip1 to Dip5: These assign the address of the corresponding monitor to its call button on the door
panel. Switches -5 must remain in the OFF position.2
1 2 3
ON
4 5 6 7 8
Apartment 1
Apartment 1 (Dip1 to ON) ART G2+ monitor with V.0 and later.4 3
*
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
4Kit Soul / Art
manual
.
Dip6-Dip7: These dene whether the monitor is master or slave. Each apartment must have one master monitor,
and only one.
Master Slave 1 Slave 2 Slave 3
1 2 3
ON
4 5 6 7 8 1 2 3
ON
4 5 6 7 8 1 2 3
ON
4 5 6 7 8 1 2 3
ON
4 5 6 7 8
1
( )
1
( )
For more information, see user manualTART 4/G2+ (code 50122527).
https://doc.golmar.es/search/manual/50122527
For more information, see user manualTART 4/G2+ (code 50122527).
https://doc.golmar.es/search/manual/50122527
A. .Speaker
- The push button led will blink in white color indicating that a
photo/video is pending viewing. Pressing will access the
recordings menu.
- The push button led will blink in white color if the function
'Doctor mode' is activated and it will turn off if the function is
deactivated.
- With the special code '0441' (Doctor mode) already entered (see
"TART 4/G2+" manual"), press the button for 5 sec. to activate/
deactivate the function.
(see "TART 4/G2+" manual)
The function of each button is shown on the monitor screen with an
icon located just above each button .
B. Function buttons, access and selection of menu functions.
C. LED:Monitor status
Yellow ON: Standby without notification.
E. .Microphone
Press to access 'Doctor mode' function (standby monitor):
Press to acces the recordings menu (standby monitor):
In call :/communication
Above these raised dots is the 'Door opening' button.
G. Micro SD card slot (not included).
Type: MicroSD Class 10 from 4 to 128 .GB GB
H. Wall mounting connector fixing (x4).
I. Configuration switches.
Red ON: Do not disturb Mode a tivated.c
J. .Installation terminals
D. 4.3"TFT colour screen.
F. people.Raised dots for the visually impaired
Above this raised dot is the 'Start/ nd communication' button.E
*
*
A
D
B
C
E
H
I
J
H
H
H
SA
GND
HZ
HZ
ON
1 2 3 4 5 6 7
8
BUS
F
BUS
12210430 V0Product Version: 4
MONITOR 4 ”ART 4/G2+.3
GOLMAR S.A.C/ Silici, 13 08940-SPAIN
WARNING
To preventfire or electric shock, do not
expose this device to rain or moisture
To prevent electric shock, do not remove cover.
CAUTION
No user serviceable parts inside.
Refer servicing to qualified service personnel
MADE IN CHINA
SA
OFF = 0
DIP 1 to 5
DIP 8
Monitor address
EOL resistor
DIP 6,7
00 - Master
10 - Slave 1
01 - Slave 2
11 - Slave 3
GND
HZ
HZ
BUS
BUS
ON = 1
G
ART /G2+4 MONITOR

Other manuals for golmar Art 4/G2+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the golmar Art 4/G2+ and is the answer not in the manual?

golmar Art 4/G2+ Specifications

General IconGeneral
Brandgolmar
ModelArt 4/G2+
CategoryIntercom System
LanguageEnglish

Related product manuals