8 www.goodmanmfg.com SS-GMH95
SS-GMH95 www.goodmanmfg.com 9
Product SPecificationS
Product SPecificationS
GCH95 airFlow data
(CFM & Temperature Rise vs. External Static Pressure)
Model
Motor
Speed
Tons
AC¹
External Static Pressure, (Inches Water Column)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM
GCH95
0453BX
High 3 1,415 28 1,352 30 1,290 31 1,196 34 1,127 36 1,035 936 825
Med 2.5 1,221 33 1,178 34 1,127 36 1,073 38 1,007 40 932 834 733
Med-Lo 2 1,034 39 1,000 40 976 41 935 43 881 46 818 733 662
Low 1.5 860 47 845 48 812 50 783 51 740 54 682 619 534
GCH95
0703BX
High 3 1,431 42 1,368 44 1,296 47 1,228 49 1,150 53 1,055 962 860
Med 2.5 1,212 50 1,182 51 1,138 53 1,091 55 1,019 59 944 871 769
Med-Lo 2 1,002 60 978 62 956 63 921 66 878 69 825 738 647
Low 1.5 813 74 805 75 790 76 759 80 726 83 689 644 605
GCH95
0704CX
High 4 1,755 34 1,674 36 1,632 37 1,510 40 1,423 42 1,325 1,241 1,116
Med 3.5 1,656 36 1,585 38 1,536 39 1,429 42 1,355 45 1,268 1,145 1,059
Med-Lo 3 1,551 39 1,488 41 1,427 42 1,353 45 1,290 47 1,195 1,100 1,017
Low 2.5 1,286 47 1,258 48 1,241 49 1,185 51 1,112 54 1,067 983 886
GCH95
0904CX
High 4 1,734 46 1,652 49 1,578 51 1,508 53 1,413 57 1,336 1,248 1,154
Med 3.5 1,642 49 1,558 52 1,487 54 1,418 57 1,336 60 1,243 1,164 1,039
Med-Lo 3 1,522 53 1,458 55 1,396 58 1,321 61 1,253 64 1,182 1,101 986
Low 2.5 1,287 63 1,244 65 1,184 68 1,148 70 1,098 73 1,034 953 849
GCH95
0905DX
High 5 2,189 37 2,109 38 2,025 40 1,948 41 1,862 43 1,757 1,644 1,537
Med 4 1,885 43 1,831 44 1,776 45 1,711 47 1,637 49 1,539 1,453 1,346
Med-Lo 3.5 1,665 48 1,627 50 1,584 51 1,524 53 1,462 55 1,400 1,323 1,220
Low 3 1,474 55 1,440 65 1,401 57 1,356 59 1,310 61 1,255 1,193 1,109
GCH93
1155DX
High 5 2,134 46 2,103 47 2,029 48 1,941 51 1,906 51 1,818 1,733 1,625
Med 4 1,678 58 1,643 60 1,643 60 1,577 62 1,527 64 1,489 1,423 1,339
Med-Lo 3.5 1,453 68 1,440 68 1,426 69 1,363 72 1,349 73 1,314 1,253 1,205
Low 3 1,259 78 1,239 79 1,220 80 1,181 83 1,159 85 1,118 1,082 1,015
¹ @0.5” ESP
No
tes:
 
 
 
 INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
 
 -
