What does flame lockout mean in a Goodman GMVM?
- CCharles MillerJul 31, 2025
A flame lockout in a Goodman Furnace occurs when the furnace shuts down due to an excessive number of ignition retries or flame recycles, typically after 3 attempts.
What does flame lockout mean in a Goodman GMVM?
A flame lockout in a Goodman Furnace occurs when the furnace shuts down due to an excessive number of ignition retries or flame recycles, typically after 3 attempts.
What to do if there is a gas interruption in my Goodman GMVM?
To address a gas interruption in your Goodman Furnace, you should locate and correct the interruption. Inspect the front cover pressure switch operation, checking the hose, wiring, and contact operation, and correct if necessary. Ensure the furnace is draining properly. Replace or realign the igniter if needed. Check the flame sense signal, and sand the sensor if it's coated or oxidized. Also, check the flue piping for any blockage, ensuring it has the correct length, elbows, and termination. Finally, verify that the induced draft blower is performing properly.
How to fix low stage pressure switch contacts sticking in Goodman GMVM Furnace?
If the low stage pressure switch contacts are sticking in your Goodman Furnace, you should replace the low stage pressure switch or repair any shorts in the wiring.
What does inducer motor overcurrent mean for Goodman GMVM Furnace?
The inducer motor has an overcurrent fault.
What is motor horsepower mismatch in Goodman Furnace?
A motor horsepower mismatch in a Goodman Furnace means that the circulator blower motor horsepower in the shared data set does not match the actual circulator blower motor horsepower.
What does it mean when my Goodman GMVM Furnace motor is sensing loss of rotor control?
The circulator blower motor senses a loss of rotor control.
What does invalid memory card data mean for Goodman GMVM Furnace?
There is invalid memory card data.
Model | GMVM |
---|---|
Heating Capacity | 40, 000 to 120, 000 BTU/h |
Heat Exchanger Material | Stainless Steel |
Fuel Type | Natural Gas or Propane |
Ignition System | Direct Spark Ignition |
Warranty | Limited Lifetime Heat Exchanger, 10-Year Parts Limited Warranty |
Guidance on understanding safety symbols and warnings in the manual.
Hazards related to carbon monoxide poisoning and necessary ventilation.
Explanation of model number coding for furnace identification.
Table showing accessory compatibility for Amana furnace models.
Information on concentric vent kits for vertical and horizontal termination.
Procedures to prevent damage from static discharge during servicing.
Minimum clearance requirements for combustible materials.
Critical requirements for combustion and ventilation air supply.
Alternative connection methods for vent/flue and combustion air.
Guidance on vertical and horizontal vent/flue pipe terminations.
Clearance requirements for direct vent terminal installations.
Connecting drain hoses for upright installations with trap on the right side.
General warnings and instructions for electrical connections.
Wiring instructions for 24V thermostats and integrated control module.
Warnings and instructions for propane gas conversion.
Procedure for measuring external static pressure.
Adjusting circulator blower speeds for heating and cooling.
Details on DIP switch functions for furnace operation.
Step-by-step procedure for starting the furnace.
Procedure for measuring gas manifold pressure.
Table of symptoms and diagnostic codes for furnace issues.
Table of status codes and their meanings for furnace operation.
Procedure for checking line voltage to the furnace.
Testing and troubleshooting the induced draft blower motor.
Measuring gas supply and manifold pressures.
Troubleshooting ignition control boards and diagnostic LEDs.
Checking and cleaning the flame sensor for proper function.