Do you have a question about the Goodman GVXC200481 and is the answer not in the manual?
Explains the function of the INVCCHK01 kit for inverter units and the problem it solves.
Comprehensive guide detailing the physical installation of the crankcase heater kit.
Identifies and describes the physical components of the Bluetooth Shared Data Loader.
Steps to download the CoolCloud app and connect the loader to HVAC equipment.
Instructions for selecting and loading shared data onto the unit using the app interface.
Specific process for loading shared data onto ComfortNet HVAC systems.
Specific process for loading shared data onto ComfortBridge HVAC systems.
Explains what shared data is, when it's needed, and fault code indicators.
Explains the function of the INVCCHK01 kit for inverter units and the problem it solves.
Comprehensive guide detailing the physical installation of the crankcase heater kit.
Identifies and describes the physical components of the Bluetooth Shared Data Loader.
Steps to download the CoolCloud app and connect the loader to HVAC equipment.
Instructions for selecting and loading shared data onto the unit using the app interface.
Specific process for loading shared data onto ComfortNet HVAC systems.
Specific process for loading shared data onto ComfortBridge HVAC systems.
Explains what shared data is, when it's needed, and fault code indicators.
The INVCCHK01 External Crankcase Heater Kit is designed for use with Goodman and Amana inverter split systems to address a specific operational characteristic: a high-pitched sound that may emanate from the outdoor unit during standby mode. This sound is a result of the compressor windings drawing a small current to maintain optimal oil temperature, a feature intended to protect the compressor and prepare it for the next run cycle. While not a defect, this sound can be objectionable to homeowners. The kit provides an alternative method for maintaining compressor oil temperature, thereby eliminating the need for the compressor windings to draw current during standby and, consequently, the associated noise.
The primary function of the INVCCHK01 kit is to disable the internal crankcase heater function, which is typically enabled in the production shared data file of inverter units, and replace it with an external crankcase heater. This external heater is controlled by a temperature switch that cycles the heater ON and OFF based on the discharge temperature during operation. This ensures the compressor oil is adequately heated before startup, preventing potential damage and ensuring smooth operation.
| Model | GVXC200481 |
|---|---|
| Type | Air Conditioner |
| Cooling Capacity (Ton) | 4 Ton |
| Refrigerant | R-410A |
| Voltage | 208/230V |
| Operating Voltage | 208/230V |
| Phase | 1 |
| Cooling Capacity | 48000 BTU |
| HSPF (Up to) | 9.0 |