Questions and Answers

  • K
    kevinharrellSep 23, 2025
    What does IFan Fail mean on my Goodwe GW12K-SDT-20 Inverter?
    • H
      hendersonjaniceSep 23, 2025
      An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
  • T
    Timothy PattersonAug 25, 2025
    How to fix an 'Over Temperature' error on my Goodwe GW12K-SDT-20 Inverter?
    • S
      Sarah HernandezAug 25, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
  • P
    paul00Aug 25, 2025
    What to do if my Goodwe Inverter displays 'Isolation Fail'?
    • B
      Brandi KingAug 26, 2025
      If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
  • B
    Brittany StanleyAug 27, 2025
    What does 'Vac Fail' mean on my Goodwe Inverter?
    • D
      Diamond StewartAug 27, 2025
      If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
  • N
    Nancy BishopAug 27, 2025
    What causes 'Fac Fail' on a Goodwe Inverter?
    • L
      Lisa HamptonAug 27, 2025
      If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
  • B
    bakergregorySep 14, 2025
    What does ARC Fault mean on a Goodwe Inverter, and how do I fix it?
    • A
      abellSep 14, 2025
      An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
  • S
    Steven BuckSep 12, 2025
    What should I do if my Goodwe Inverter displays a PV Over Voltage error?
    • R
      Ryan MccarthySep 12, 2025
      A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
  • J
    Jacob MackSep 13, 2025
    Why does my Goodwe GW12K-SDT-20 Inverter show a Fac Fail error?
    • F
      fsimsSep 13, 2025
      A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
  • D
    Donna MurraySep 5, 2025
    What does 'IFan Fail' mean on my Goodwe GW12K-SDT-20?
    • A
      adamaliSep 5, 2025
      If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
  • M
    Michelle SpencerSep 2, 2025
    What does 'DC Bus High' mean on my Goodwe GW12K-SDT-20 Inverter?
    • L
      lwalkerSep 2, 2025
      If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.

Summary

Safety Precaution

2.1 General Safety

General safety guidelines for installation and operation.

2.2 DC Side Safety

Safety precautions specific to the DC side connections.

2.3 AC Side Safety

Safety precautions specific to the AC side connections.

Installation

5.1 Installation Requirements

Covers environmental, mounting, angle, and tool requirements for installation.

5.2 Inverter Installation Steps

Details the process of moving and physically installing the inverter.

Electrical Connection

6.1 Safety Precautions

Safety guidelines for all electrical connection procedures.

6.3 PV Input Cable Connection

Procedure for connecting the DC input cables from PV modules.

6.4 AC Output Cable Connection

Procedure for connecting the AC output cable to the grid.

Equipment Commissioning

System Commissioning

Maintenance

Technical Parameters

Goodwe GW12K-SDT-20 Specifications

General IconGeneral
ModelGW12K-SDT-20
Rated Output Power12000W
Input Voltage Range200 - 1000 V
Max. DC Input Voltage1100 V
MPPT Voltage Range200 - 850 V
Nominal AC Output Power12000W
Number of MPPT2
Protection DegreeIP65
Weight22 kg
Max. DC Input Power18000W
Max. AC Output Power13200 W
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Cooling