Questions and Answers

  • W
    William GuerreroSep 23, 2025
    What does IFan Fail mean on my Goodwe GW10KAU-DT?
    • A
      Ann SmithSep 23, 2025
      An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
  • T
    Terry ByrdAug 25, 2025
    How to fix an 'Over Temperature' error on my Goodwe GW10KAU-DT Inverter?
    • M
      mcgrathcindyAug 25, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
  • K
    kristinrobertsonAug 25, 2025
    What to do if my Goodwe GW10KAU-DT displays 'Isolation Fail'?
    • W
      William SanchezAug 26, 2025
      If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
  • D
    davidlorettaAug 27, 2025
    What does 'Vac Fail' mean on my Goodwe GW10KAU-DT?
    • J
      jennapachecoAug 27, 2025
      If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
  • B
    brandon76Aug 27, 2025
    What causes 'Fac Fail' on a Goodwe GW10KAU-DT?
    • I
      Ivan MendezAug 27, 2025
      If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
  • M
    Mark WilliamsSep 14, 2025
    What does ARC Fault mean on a Goodwe Inverter, and how do I fix it?
    • J
      Jeremy SchmidtSep 14, 2025
      An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
  • D
    davidsonkathySep 12, 2025
    What should I do if my Goodwe GW10KAU-DT displays a PV Over Voltage error?
    • J
      jennifer95Sep 12, 2025
      A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
  • J
    jparsonsSep 13, 2025
    Why does my Goodwe Inverter show a Fac Fail error?
    • K
      Kathy SampsonSep 13, 2025
      A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
  • P
    patrick35Sep 5, 2025
    What does 'IFan Fail' mean on my Goodwe Inverter?
    • A
      alexis68Sep 5, 2025
      If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
  • J
    jonathanmillerSep 2, 2025
    What does 'DC Bus High' mean on my Goodwe GW10KAU-DT Inverter?
    • J
      jonesashleySep 2, 2025
      If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.

Summary

Safety Precautions

DC Side Safety Considerations

Details safety measures for DC connections and PV arrays, including grounding and voltage.

AC Side Safety Considerations

Outlines safety rules for AC connections, covering voltage, frequency, and protective devices.

Inverter Installation Safety

Addresses safety during inverter mounting, terminal load, labels, and hazard symbols.

Installation

Installation Site Requirements

Outlines environmental needs for installation: location, ventilation, temperature, humidity, and mounting support.

Moving and Mounting the Inverter

Details the process for moving and physically installing the inverter onto its mounting plate, with safety.

Electrical Connection

Electrical Connection Safety

Warns about electrical hazards during connection, emphasizing powering off and following regulations.

PE Cable Connection Procedure

Explains how to connect the Protective Earth (PE) cable, including cable specs and grounding.

PV Input Cable Connection

Details connecting PV input cables, including voltage, current limits, polarity, and connector types.

AC Output Cable Connection

Explains how to connect the AC output cable, including recommended circuit breakers and cable specs.

Equipment Commissioning

Pre-Power-On Checklist

Lists essential checks before powering on the inverter, ensuring correct installation and connections.

System Commissioning

Parameter Settings via LCD

Guides users on navigating the LCD menu and setting parameters, including menu structure and descriptions.

Maintenance

Technical Parameters

Goodwe GW10KAU-DT Specifications

General IconGeneral
ModelGW10KAU-DT
Rated Output Power10000W
Number of MPPT2
Frequency50/60Hz
Total Harmonic Distortion (THD)<3%
DC SwitchYes
Protection ClassIP65
Rated AC Voltage230 V
AC Voltage Range180-280V
Power Factor0.8 leading to 0.8 lagging
Operating Temperature Range-25 ~ +60°C
CommunicationRS485

Related product manuals