User Manual
Grid-Tied PV Inverter
SDT G2 Series
V1.0-2022-01-17

Other manuals for Goodwe GW10K-SDT-20

Questions and Answers

  • M
    Misty HarmonSep 23, 2025
    What does IFan Fail mean on my Goodwe GW10K-SDT-20?
    • Y
      yolanda86Sep 23, 2025
      An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
  • L
    Lauren WrightAug 25, 2025
    How to fix an 'Over Temperature' error on my Goodwe GW10K-SDT-20?
    • H
      Hannah SalasAug 25, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
  • A
    Andrew HuntAug 25, 2025
    What to do if my Goodwe GW10K-SDT-20 Inverter displays 'Isolation Fail'?
    • E
      Elizabeth CampbellAug 26, 2025
      If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
  • J
    James FarleyAug 27, 2025
    What does 'Vac Fail' mean on my Goodwe Inverter?
    • R
      Rebecca NobleAug 27, 2025
      If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
  • A
    Ashley MillerAug 27, 2025
    What causes 'Fac Fail' on a Goodwe Inverter?
    • S
      Steven CarrAug 27, 2025
      If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
  • V
    Vincent GreenSep 14, 2025
    What does ARC Fault mean on a Goodwe GW10K-SDT-20, and how do I fix it?
    • L
      Laura WoodSep 14, 2025
      An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
  • W
    Wesley MoyerSep 12, 2025
    What should I do if my Goodwe Inverter displays a PV Over Voltage error?
    • R
      Rachel MitchellSep 12, 2025
      A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
  • S
    shirley61Sep 13, 2025
    Why does my Goodwe GW10K-SDT-20 show a Fac Fail error?
    • S
      scott13Sep 13, 2025
      A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
  • M
    Michael Carpenter MDSep 5, 2025
    What does 'IFan Fail' mean on my Goodwe GW10K-SDT-20 Inverter?
    • E
      Emily AlexanderSep 5, 2025
      If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
  • D
    Danielle BrewerSep 2, 2025
    What does 'DC Bus High' mean on my Goodwe GW10K-SDT-20 Inverter?
    • A
      andersondeniseSep 2, 2025
      If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.

Summary

Safety Precautions

General Safety Guidelines

Outlines essential safety rules for installation and operation.

DC Side Safety

Specific safety instructions for the DC electrical connections.

AC Side Safety

Safety measures related to AC electrical connections and grid requirements.

Installation

Installation Requirements

Specifies suitable locations and conditions for inverter installation.

Installing the Inverter

Step-by-step guide for securing the inverter on the mounting plate.

Electrical Connection

Electrical Connection Safety

Essential safety rules before making electrical connections.

Grounding (PE) Cable Connection

How to correctly connect the protective earth cable.

PV Input Cable Connection

Procedure for connecting the solar panel DC input cables.

AC Output Cable Connection

Steps for connecting the inverter to the AC grid.

Equipment Commissioning

Pre-Power On Checks

Checklist before switching the inverter on for the first time.

Power On Procedure

Sequence of operations to safely power up the inverter.

System Commissioning

Maintenance

Goodwe GW10K-SDT-20 Specifications

General IconGeneral
ModelGW10K-SDT-20
Number of MPPT2
Nominal Grid Frequency50/60Hz
THDi<3%
DC SwitchYes
Protection ClassI
Protection LevelIP65
Rated Power10kW
Maximum Power Output11kW
Nominal AC Output Power10kW
Max. AC Apparent Power11kVA
Nominal AC Voltage220/230V
AC Voltage Range180-280V
Power Factor0.8 leading ~ 0.8 lagging
Operating Temperature Range-25°C to 60°C
CommunicationWiFi/GPRS/RS485