EasyManua.ls Logo

Goodwe GW15K-SDT-20 - User Manual

Goodwe GW15K-SDT-20
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
Grid-Tied PV Inverter
SDT G2 Series
V1.0-2022-01-17

Other manuals for Goodwe GW15K-SDT-20

Questions and Answers

  • L
    Lauren CohenSep 23, 2025
    What does IFan Fail mean on my Goodwe GW15K-SDT-20?
    • C
      Courtney HughesSep 23, 2025
      An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
  • C
    Catherine LittleAug 25, 2025
    How to fix an 'Over Temperature' error on my Goodwe GW15K-SDT-20 Inverter?
    • S
      sanderskarenAug 25, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
  • M
    Michelle LittleAug 25, 2025
    What to do if my Goodwe GW15K-SDT-20 Inverter displays 'Isolation Fail'?
    • T
      Tanya FordAug 26, 2025
      If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
  • T
    Tyler LynchAug 27, 2025
    What does 'Vac Fail' mean on my Goodwe GW15K-SDT-20 Inverter?
    • C
      Cynthia WhiteAug 27, 2025
      If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
  • M
    Morgan CollierAug 27, 2025
    What causes 'Fac Fail' on a Goodwe Inverter?
    • D
      dhigginsAug 27, 2025
      If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
  • M
    Mr. Nicholas SchultzSep 14, 2025
    What does ARC Fault mean on a Goodwe Inverter, and how do I fix it?
    • D
      Dustin ChavezSep 14, 2025
      An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
  • S
    Samantha JohnsonSep 12, 2025
    What should I do if my Goodwe GW15K-SDT-20 Inverter displays a PV Over Voltage error?
    • K
      Katherine ArnoldSep 12, 2025
      A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
  • A
    Adam MarquezSep 13, 2025
    Why does my Goodwe GW15K-SDT-20 show a Fac Fail error?
    • A
      angelica20Sep 13, 2025
      A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
  • L
    lisa03Sep 4, 2025
    What does 'IFan Fail' mean on my Goodwe GW15K-SDT-20?
    • F
      frankbrownSep 5, 2025
      If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
  • R
    Riley BlackSep 2, 2025
    What does 'DC Bus High' mean on my Goodwe GW15K-SDT-20?
    • K
      kvasquezSep 2, 2025
      If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.

Summary

Safety Precautions

General Safety Guidelines

Provides essential safety rules for installation and operation, including PPE and manual adherence.

Inverter Installation Safety

Highlights safety warnings and symbols related to the physical installation of the inverter.

Installation Guide

Installation Requirements

Details environmental, mounting, and angle requirements for installing the inverter safely and correctly.

Electrical Connections

Electrical Connection Safety

Emphasizes critical safety warnings and protective equipment for electrical connections.

Grounding (PE) Cable Connection

Details the procedure and specifications for connecting the protective earth (PE) cable.

PV Input Cable Connection

Provides instructions and warnings for connecting the DC input cables from the PV array.

AC Output Cable Connection

Explains how to connect the AC output cable, including AC breaker recommendations.

Equipment Commissioning

Pre-Power On Checks

Lists essential checks before energizing the inverter and grid connection.

Power On Procedure

Describes the sequence for turning on the inverter's power switches.

System Commissioning and Settings

Inverter Parameter Settings via LCD

Guides on navigating the LCD menu for configuring inverter parameters.

Maintenance Procedures

Inverter Power Off Procedure

Details the correct steps to safely power down the inverter before performing maintenance.

Troubleshooting Common Issues

Offers guidance on diagnosing and resolving common inverter faults and errors.

Technical Parameters

Model-Specific Technical Specifications

Detailed technical specifications for various inverter models, including input, output, and protection features.

Goodwe GW15K-SDT-20 Specifications

General IconGeneral
ModelGW15K-SDT-20
Rated Output Power15000W
THDi<3%
Protection DegreeIP65
Number of MPPT2
AC Output Frequency50/60 Hz
Rated AC Voltage400 V
Power Factor0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to 60°C
Humidity Range0-100%
CommunicationRS485/Optional: Wi-Fi, Ethernet
AC Output Voltage400 V

Related product manuals