Questions and Answers

  • J
    Julie SmithSep 23, 2025
    What does IFan Fail mean on my Goodwe GW15KAU-DT Inverter?
    • J
      Jacob BellSep 23, 2025
      An IFan Fail error on your Goodwe Inverter indicates a fault in the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally.
  • N
    Nicole EstradaAug 25, 2025
    How to fix an 'Over Temperature' error on my Goodwe GW15KAU-DT Inverter?
    • G
      Gregory ThomasAug 25, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' error, there are a few things to check: 1. Ensure that the inverter has adequate ventilation and space for heat dissipation. 2. Verify that the ambient temperature is not too high. 3. Confirm that the fans are working correctly and are not blocked.
  • N
    Nicole HallAug 25, 2025
    What to do if my Goodwe Inverter displays 'Isolation Fail'?
    • M
      michaelmatthewsAug 26, 2025
      If your Goodwe Inverter is showing an 'Isolation Fail' error, it could be due to: 1. A short circuit to the ground in the PV system. Check the PV input cables for any breaks. 2. A moist environment affecting the PV system's insulation. Ensure the module frames and metal bracket are securely grounded. 3. Also, check that the AC side is properly grounded.
  • J
    joel76Aug 27, 2025
    What does 'Vac Fail' mean on my Goodwe Inverter?
    • S
      Samantha MccannAug 27, 2025
      If your Goodwe Inverter shows 'Vac Fail', it means the utility grid voltage is out of the allowed range. Make sure that the grid voltage is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly.
  • G
    gdavisAug 27, 2025
    What causes 'Fac Fail' on a Goodwe GW15KAU-DT Inverter?
    • H
      Heather MartinezAug 27, 2025
      If your Goodwe Inverter shows 'Fac Fail', it indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices under the same grid connection point is working normally, and whether the main supply is normal. Ensure the grid frequency is within the allowed range and that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly. If the fault happens occasionally, it may be due to instantaneous utility grid frequency change and does not need to be handled.
  • J
    Julie MunozSep 14, 2025
    What does ARC Fault mean on a Goodwe GW15KAU-DT Inverter, and how do I fix it?
    • S
      stephenscourtneySep 14, 2025
      An ARC Fault error on your Goodwe Inverter suggests that the PV string cables are arcing or are in poor contact. Check whether the PV terminals and cables are connected properly. Clear the error messages.
  • C
    Charles KeithSep 12, 2025
    What should I do if my Goodwe Inverter displays a PV Over Voltage error?
    • D
      Daniel BurchSep 12, 2025
      A PV Over Voltage error on your Goodwe Inverter can occur if excess PV modules are connected in series, causing the open-circuit voltage to be higher than the operating voltage. Check whether the PV string input voltage is consistent with the value displayed on the LCD and verify that the PV string voltage meets the maximum input voltage requirements.
  • N
    Nicole JohnsSep 13, 2025
    Why does my Goodwe GW15KAU-DT show a Fac Fail error?
    • J
      John TaylorSep 13, 2025
      A Fac Fail error on your Goodwe Inverter indicates that the utility grid frequency is out of the allowed range. Check whether other electrical devices connected to the same grid connection point are working normally, and whether the main supply is normal. Make sure that the grid frequency is within the allowed range. Also, ensure that the phase sequence of the AC cables are connected correctly, and the neutral wire and PE cable are properly and firmly connected. Pay attention to the frequency of the fault. If it happens occasionally, the fault may be caused by the instantaneous utility grid frequency change and does not need to be handled.
  • L
    Lisa SmithSep 4, 2025
    What does 'IFan Fail' mean on my Goodwe GW15KAU-DT?
    • B
      Brittany WilkinsonSep 5, 2025
      If your Goodwe Inverter shows 'IFan Fail', it means there is a fault with the internal fan of the inverter. Restart the inverter and check whether the inverter can work normally. For internal fan faults, contact after-sales service.
  • S
    Sara ContrerasSep 2, 2025
    What does 'DC Bus High' mean on my Goodwe GW15KAU-DT?
    • R
      Roberto SchultzSep 2, 2025
      If your Goodwe Inverter shows 'DC Bus High', it may indicate an internal fault. Ensure that the software version is the latest one. You can also try restarting the inverter to see if it resolves the issue.

Summary

Safety Precaution

General Safety

Overall safety rules for installation, operation, and maintenance of the inverter.

DC Side Safety

Specific safety measures and warnings for DC electrical connections.

AC Side Safety

Safety considerations and precautions for AC electrical connections.

Installation

Installation Requirements

Environmental and mounting conditions for safe and effective installation.

Inverter Installation Procedure

Step-by-step guide for mounting the inverter onto its support.

Electrical Connection

Electrical Safety Precautions

Critical safety measures to observe during all electrical connections.

PE Cable Connection

Procedure for connecting the protective earth (ground) cable for safety.

PV Input Cable Connection

Steps for connecting the DC input cables from solar panels to the inverter.

AC Output Cable Connection

Guide for connecting the AC output cable to the electrical grid.

Equipment Commissioning

System Commissioning

Parameter Settings via LCD

Guide to configuring inverter settings using the built-in LCD interface.

Maintenance

Power Off the Inverter

Steps to safely shut down the inverter before performing tasks.

Troubleshooting Guide

Steps to diagnose and resolve common inverter faults and errors.

Goodwe GW15KAU-DT Specifications

General IconGeneral
ModelGW15KAU-DT
TypeString inverter
Rated Power15000W
Max. DC Voltage1100 V
Maximum PV Input Voltage1100 V
Start Voltage200 V
Number of MPPT2
Nominal AC Voltage400 V
AC Output Voltage400 V
AC Output Frequency50/60Hz
MPPT Efficiency99.9%
Protection DegreeIP65
Max. DC Power22500W
Max. AC Power15000 W
AC Voltage Range310-480 V
European Efficiency97.5%
Operating Temperature Range-25 °C to +60 °C
CommunicationWi-Fi, RS485, Ethernet