Model HSC
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTRUCTION MANUAL
IM008R04
Question and Answer IconNeed help?

Do you have a question about the Goulds Pumps HSC and is the answer not in the manual?

Goulds Pumps HSC Specifications

General IconGeneral
TypeCentrifugal
ModelHSC
HorsepowerVaries with model
Discharge SizeVaries with model
ApplicationIndustrial, Commercial
Maximum Flow Rate2000 GPM
Maximum Head300 ft
Impeller DiameterVaries with model
SpeedVaries with model
Suction SizeVaries with model
MaterialCast Iron, Stainless Steel

Summary

Important Information

Motor Protection Details

Covers thermal protection, overload requirements, and switch selection.

Maximum Operating Limits

Specifies limits for liquid temperature, working pressure, and start frequency.

Service Life and Maintenance Schedule

Guidance on regular inspection and maintenance for extended service life.

Installation Procedures

Pump Location and Piping Support

Advice on pump placement, adequate space, and independent piping support.

Fittings and Orientation

Guidance on selecting fittings, avoiding stress, and unit orientation.

Electrical Safety During Installation

Warning to always disconnect electrical power when handling pump or controls.

Suction Piping

Low Static Suction Lift

Desired conditions for suction piping, consulting NPSHR for lifts above 15'.

Pipe Sizing and Reducers

Ensuring suction pipe is at least pump connection size; using eccentric reducers.

Installation with Pump Above Source

Avoiding air pockets, sloping piping upward, ensuring airtight joints.

Discharge Piping

Check and Gate Valve Arrangement

Requirement for a check valve between gate valve and pump for regulation/inspection.

Increaser Placement

Positioning an increaser between the check valve and pump if required.

Threaded Connection Sealing

Using Teflon tape to seal threaded connections for proper sealing.

Rotation and Operation

Checking Shaft Rotation

Verifying correct right-hand (clockwise) rotation by quick power cycling.

Startup Procedures

Ensuring pump is primed, discharge valve partially open before starting.

Post-Operation Check

Performing a complete check after the unit stabilizes under operating conditions.

Maintenance and Disassembly

Bearing Lubrication

Motor ball bearings are permanently lubricated and require no greasing.

Running Dry Warning

Caution against running the pump dry to prevent seizing and seal damage.

Disassembly Steps

Outline of procedures for disassembling the pump liquid-end.

Reassembly and Troubleshooting

Mechanical Seal Reassembly

Ensuring seal components are in good condition for proper function.

Impeller and Wear Ring Inspection

Checking impellers and wear rings for wear, degradation, or blockages.

Troubleshooting Common Issues

Guide to diagnosing and resolving common problems like motor not running or low delivery.

Parts List

Component Identification

List of pump parts with item numbers, names, quantities, and motor codes.

Motor Specifications

Details on motor horsepower, model numbers, and corresponding order numbers.

Commercial Warranty

Warranty Period

One-year warranty from installation or twelve months from shipment date.

Repair or Replacement Process

Buyer's responsibility for notice, costs, and Seller's option for repair/replacement.

Warranty Exclusions

List of conditions and actions that void the warranty or are not covered.