6)SERVICE
a.Haveyourpowertoolservicedbyaqualified
repairpersonusingonlyidentical
replacementparts.Thiswillensurethatthe
safetyofthepowertoolismaintained.
b.Neverserviceadamagedbattery.Serviceof
batteryshouldonlybeperformedbythe
manufacturerorauthorizedservice
providers.
VACUUMLIFTINGDEVICESAFETY
WARNINGS/INSTRUCTIONS
a.Donotdeliberatelytrytoriptheloadoff
withextremeforce.Thereisariskofthe
loadcrushingfeetandhandsanddamaging
theobjectandtool.
b.Donotliftobjectsweighingmorethan170
kg(375lbs).Thereisarisktheweightcanfall
off.
c.Riskofloadcrushingfeetandhandsand
damagingtheobjectandtool.Donotshake
thetoolwhilelifting,movingandplacing
objects.Donotswingorshaketheload
whilelifting,movingandplacingobjects.Do
notusethetoolwhenthesealiswornout.
Liftandcarrytheloadwithuniformspeed
withoutsuddensharpandstrong
movements.
d.Donotusethetoolwhilethebatteryislow.
Thereisariskofinjuryanddamagetothe
materialsbeinglifted.
e.Ifthesealingforcebeginstonoticeably
decreasewhilethebatteryisfullycharged,
checktherubberfoamsealforwearand
tearordamage.Donotattempttolift
anythingwiththetooluntilyouhave
replacedtheseal.
f.Usecautionwhenliftinglargethinflexible
sheets,likedrywall,cardboard,plastic,
plywood,thinsheetmetaletc.Thinsheets
bendandflexandcanunexpectedlychange
curvatureabovetheirlimitanddetach.
g.
Donotattachthetooltosurfaceswith
visiblepuddlesofwater.Internal
componentsarenotwaterproof.Ifwateris
suckedintotheairductsitcancause
permanentdamagetothetool.TheNemo
GRABO®isnotwaterproofandtherefore
extremecautionshouldbetakenwhen
usingitintherainorwetconditions.
h.
Donotdropthetoolfromheightsabove1.5
meterabovetheground(chestlevel).If
droppedbyaccident,inspectthesealside
lipsfordamage.
i.Donotplaceheavyobjectsontopofthe
tool.
j.Toavoidoverheating,donotcoverthetool.
k.Ensuretheswitchisintheoff-position
beforetransportingthetoolandwhenin
storage.Bemindfulthatthetoolisnot
switchedonaccidently.
l.NOTICE:Duetothehighpressurethatis
createdwiththeNemoGRABO®we
stronglyrecommendthatyoudonot
attempttoattachtheNemoGRABO®to
glassthinnerthan6mmthick.Damagecan
occurtoglassthatisthinnerthan6mm
thick.
!WARNING:Weightmaydropwithout
warningifthesafetyprecautionsarenot
kept!TheNemoGRABO®createsastrong
vacuum.Incasethesealisbrokenorthe
allowedweightisexceededoranyother
factorthatcausesthenegativepressureto
releasespontaneously,thiskindoffailure
willhappenverysuddenlyandabsolutely
withoutanysensoryindicationorwarning.
Youwillnotnoticetheweightdetaching
andtherewillbenopossibilitytostopor
catchit.Thisisverydangerous,especially
withheavyloads.Thereforeallsafety
precautionsshouldbekepttothe
maximum.