Technical Data
308883W 15
Technical Data
.
50:1 Fire-Ball
®
300 Pumps
US Metric
Fluid pressure ratio 50:1
Air pressure operating range 30 to 140 psi 0.3 to 0.97 MPa,3 to 9.7 bar
Maximum fluid working pressure 8400 psi 58 Mpa, 580 bar
Maximum output 0.22 gpm 0.82 lpm
Cycles per gallon (liter) 345 92
Maximum recommended pump speed 76 cycles/min at 0.22 gpm 76 cycles/min at 0.82 lpm
Air motor effective diameter 3.0 in. 76 mm
Stroke - -
Air consumption Approximately 22.8 cfm at 0.25
gpm at 100 psi
Approximately 0.638 m
3
/min at
0.95 lpm at 0.7 MPa/7 bar
Wetted Parts Steel, brass, aluminum, acetal, nitrile rubber, polyurethane
Weight 22 lb 10 kg
Sound Level
Sound Pressure Level (Measured at 1 meter from unit) 77.8 dB(A)
Sound Power Level (tested in accordance with ISO
9614-2)
85.6 dB(A)