Startup
3A6400A 17
Startup
1. Place suction tube and drain tube in grounded metal
pail partially filled with flushing fluid. Attach ground
wire to pail and to earth ground.
2. Turn prime valve down to DRAIN position. Turn
pressure control counterclockwise to lowest
pressure.
3. Set pump switch OFF.
4. Start Engine
a. Move fuel valve to open.
b. Move choke to closed.
c. Set throttle to fast.
d. Set engine switch to ON.
5. Pull rope to start engine.
6. Increase pressure enough to start pump stroking
and allow fluid to circulate for 15 seconds; turn
pressure down and turn prime valve forward to
SPRAY position.
7. Disengage spray gun trigger lock.