Startup
3A6491E 17
8. Move gun to paint pail and trigger for 20
seconds. Release trigger and allow
sprayer to build pressure. Engage
trigger lock.
9. Inspect for leaks. If leaks occur, perform
Pressure Relief Procedure, page 12,
then tighten all fittings and repeat
Startup procedure. If there are no leaks
continue with the next step.
10. Screw tip assembly onto gun and
tighten. See Spray Tip Installation,
page 18. For gun assembly instructions,
see separate gun manual.
High-pressure spray is able to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.