Pressure Relief Procedure
12 3A6491E
Pressure Relief Procedure
Follow the Pressure Relief
Procedure whenever you see this
symbol.
1. Turn ON/OFF switch to the OFF
position.
2. Engage the trigger lock.
3. Turn pressure control to the lowest
setting.
4. Put drain tube in a pail and turn prime
valve down to relieve pressure. Leave
prime valve in the down (drain) position
until you are ready to spray again.
5. Hold a metal part of the spray gun firmly
to a grounded metal pail. Point spray gun
into pail. Disengage the trigger lock and
trigger the spray gun to relieve pressure.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection, splashed fluid
and moving parts, follow the Pressure
Relief Procedure whenever sprayer is
stopped and before sprayer is cleaned or
checked, and before equipment is
serviced.