2 Antifreezing protection: the same with that in COOL mode.
7.2.3 FAN mode
The control condition of AUTO fan speed:
If Tamb>Tset +4℃,set High speed automatically.
If Tset+2℃≤TambTset+4, set Med speed automatically.
If TambTset+2, set Low speed automatically
In this mode, the indoor fan can select High, Med, Low and Auto mode and both the compressor and outdoor fan stop ruuning.
In this mode, the temperature setting range is 16~30
7.2.4 HEAT mode
1. The condition and process of heating
If TambTset+2℃,HEAT mode will actthe compressor, outdoor fan and reversal valve will run at the same time, and the
indoor fan will run in anti-cold-wind mode.
If Tset+2℃<TambT set +5,the unit will keep running in the original mode.
If TambTset +5℃,the compressor will stop, the outdoor fan will delay 30sec to stop and the indoor fan will blow at the low
speed for 90sec and then stop.
11
Ambient temperature Tamb
COOL mode will act
DRY mode will act
COOL mode will stop
Set temperature Tset
Tset -2
Low s
p
eed Low s
p
eed Low s
p
eed
Run Stop
Compressor
Outdoor fan
Indoor fan
Ambient temperature Tamb
Tset +4
Tset +2
Indoo
r
Low s
p
eed Med s
p
eed Hi
g
h s
p
eed
Ambient temperature Tamb
Set temperature Tset
HEAT mode will stop
Keep running in original state
HEAT mode will act
Tset +5
Tset +2
3 min
Anti-cold-wind mode
Low
speed
Anti-cold-wind mode
Run Stop
Compressor
Outdoor fan
Indoor fan
Reversal valve