Operating Procedures / Photos
Disassemble Electric Box
grounding nut, disconnect the terminal of the motor
motor terminal
Screw
tube sensor
grounding nut
Unscrew the two screws fixing the electric box,
loosen the clasp, pull out the tube sensor, unscrew
and remove the electric box.
(refer to Fig. 7-8)
Fig. 7-8
Fig. 7-9
Fig. 7-10
Fig. 7-11
Fig. 7-12
Disassemble Evaporator
(refer to Fig. 7-11)
Screw
Screw
Screw
Screw
Unscrew the screws fixing the evaporator; one on
the left, two on the right.
(refer to Fig. 7-9,7-10)
Manually lift the left side of evaporator,and push
backward to let the side clasp of evaporator out
of the groove. Carefully take out the evaporator
and pay attention to protect the connecting pipe.
Disassemble Motor
Unscrew the 3 screws fixing the motor clamp to
remove the clamp.
Unscrew the holding nut fixing the cross flow fan,
pull out the motor from the cross flow fan.
(refer to Fig. 7-12)
right clamp of motor
Disassemble Cross Flow Fan
Refer to the above step, after pull out the motor,
yor can remove the cross flow fan from the base.
(refer to Fig. 7-12)