EasyManua.ls Logo

Gree GDN10AH-K4EBB1C

Gree GDN10AH-K4EBB1C
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
Service Manual
Installation and Maintenance
centrifugal louver
nut
ProcedureStep
motor
screws
electric box assembly
8.Remove centrifugal louver
9.Remove pressing wire board
10.Remove motor
11.Remove electric box assembly
Pull out the power cord, wiring of liquid
level switch, compressor wiring connect to
mainboard, unscrew screws xing electric
box to remove electric box assembly.
Remove th e motor wire conn ect to
mainboard and ground wire connect to
evaporator side plate, unscrew 3 screws
xing motor to remove motor.
Extrude the two sides of pressing wire
board, then pull the pressing wire board
outwards.
Remove nuts and washer xing louver of
motor axle, along the motor axle direction
to pull out louver.
pressing wire board
screws

Related product manuals