EasyManua.ls Logo

Gree GMV-H224WL/A-X

Gree GMV-H224WL/A-X
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC Inverter Multi VRF System
6
Fig.2
3.3 Piping Work Requirements
Refer to the table below for piping work requirements:
R410A Refrigerant System
Outer diameter (mm/inch)
Wall thickness(mm)
Φ6.35(1/4)
0.8
Φ9.52(3/8)
0.8
Φ12.70(1/2)
0.8
Φ15.9(5/8)
1.0
Φ19.05(3/4)
1.0
Φ22.20(7/8)
1.2
Φ25.40(8/8)
1.2
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.

Table of Contents

Other manuals for Gree GMV-H224WL/A-X

Related product manuals