Owner's Manual
Original Instructions
Commercial Air Conditioners
Multi Variable Air Conditioners
Ducted Type Indoor Unit
Models:
GMV-ND22PHS/B-T GMV-ND25PHS/B-T GMV-ND28PHS/B-T GMV-ND32PHS/B-T
GMV-ND36PHS/B-T GMV-ND40PHS/B-T GMV-ND45PHS/B-T GMV-ND50PHS/B-T
GMV-ND56PHS/B-T GMV-ND63PHS/B-T GMV-ND71PHS/B-T GMV-ND80PHS/B-T
GMV-ND90PHS/B-T GMV-ND100PHS/B-T GMV-ND112PHS/B-T GMV-ND125PHS/B-T
GMV-ND140PHS/B-T GMV-ND160PHS/B-T GMV-ND180PHS/B-T

Other manuals for Gree GMV-ND56PHS/B-T

Questions and Answers

  • S
    Sarah RollinsAug 18, 2025
    Why is my Gree GMV-ND56PHS/B-T not cooling properly?
    • D
      Derek FisherAug 18, 2025
      If your Gree Air Conditioner isn't cooling well, several factors could be at play. Ensure the filter is clean, as a dirty filter restricts airflow. Reduce the heat load in the room by minimizing the number of people or heat-generating devices. Check that all doors and windows are closed to prevent warm air from entering. Clear any obstructions from the indoor unit's inlet and outlet. Make sure the set temperature isn't too high; lower it for better cooling. Finally, insufficient refrigerant due to leaks can cause poor cooling, so check refrigerant levels and recharge if needed.
  • H
    Heidi ValdezAug 20, 2025
    How to troubleshoot a Gree Air Conditioner that won't start?
    • J
      jennifer60Aug 21, 2025
      If your Gree Air Conditioner isn't starting, first, check if the power supply is properly connected. Second, examine the circuit breaker to ensure it hasn't tripped due to a leakage of electricity. Also, make sure the input voltage meets the required level. If none of these steps work, the main PC-board may be defective, and you should contact an authorized service center for repair.
  • A
    Andrew RobbinsAug 23, 2025
    Why is my Gree Air Conditioner not heating well?
    • N
      Nicholas HayesAug 23, 2025
      If your Gree Air Conditioner's heating isn't effective, start by cleaning or replacing the dirty filter. Ensure all doors and windows are closed to prevent heat loss. If the set temperature is too low, increase it. Also, check for refrigerant leaks and recharge if necessary, as insufficient refrigerant can cause poor heating.
  • C
    Colleen BlackAug 26, 2025
    What to do if my Gree GMV-ND56PHS/B-T Air Conditioner stops running after a short time?
    • S
      Stephanie DavisAug 26, 2025
      If your Gree Air Conditioner stops after running for a while, it might be because the inlet or outlet of the outdoor (ODU) or indoor unit (IDU) are blocked. Remove any obstacles that are blocking these to ensure proper airflow.
  • L
    lisayoungAug 27, 2025
    How to fix mode shock in Gree Air Conditioner?
    • R
      Richard PattonAug 27, 2025
      If your Gree Air Conditioner is experiencing mode shock, try resetting the unit to eliminate the mode shock.
  • D
    Darlene SalinasAug 30, 2025
    Why doesn't the indoor fan start up on my Gree GMV-ND56PHS/B-T during heating?
    • T
      Terri DanielAug 30, 2025
      When heating starts, the indoor unit (IDU) fan might not operate immediately. This is to prevent cool air from being delivered until the heat exchange warms up; allow time for the heat exchange to warm up. Also, during defrosting, the IDU fan may stop because the system switches to cooling mode to prevent cool air from being delivered; the fan will resume operating after defrosting is complete.
  • S
    Samantha HernandezSep 1, 2025
    What to do if my Gree GMV-ND56PHS/B-T shows a communication malfunction?
    • S
      stacy75Sep 1, 2025
      If your Gree Air Conditioner displays a communication malfunction, the first step is to check the communication wiring to ensure it is properly connected.
  • D
    Darren WiseSep 3, 2025
    What to do if Gree GMV-ND56PHS/B-T Air Conditioner shows water overflow protection?
    • M
      Michael RaySep 3, 2025
      If your Gree Air Conditioner is experiencing water overflow protection, examine the water drainage system for any blockages that may be causing the issue.
  • G
    gwarnerSep 5, 2025
    Why does my Gree Air Conditioner show indoor fan protection?
    • O
      oconnellrobertSep 6, 2025
      If your Gree Air Conditioner displays an indoor fan protection error, ensure the fan is not obstructed or frozen, which may be triggering the protection mechanism.
  • C
    Crystal SmithSep 8, 2025
    Why Gree GMV-ND56PHS/B-T Air Conditioner shows freeze prevention protection?
    • J
      Jason HudsonSep 8, 2025
      If your Gree Air Conditioner is showing freeze prevention protection, ensure that the unit is not exposed to extreme cold, as this could trigger the protection mechanism.

Summary

Safety Precautions and Warnings

General Safety Warnings

Covers warnings about severe, slight, prohibited, and mandatory operations.

Installation Environment & System Compatibility

Warns against specific environments and ensures system compatibility.

Grounding & Refrigerant Safety

Emphasizes proper grounding and R410A refrigerant precautions.

Electrical & Unit Operation Safety

Power Cord & Electrical Safety

Details power cord requirements, replacement, and electrical box safety.

Unit Operation & Cleaning Safety

Covers unit operation, nitrogen, short circuits, controller use, and cleaning safety.

Environmental & Operational Precautions

Discusses volatile liquids, room ventilation, and temperature settings.

Abnormal Conditions & Repair Guidelines

Product Disposal Information

Product Introduction

Key Components & Working Conditions

Identifies main parts and lists rated working conditions.

Installation Preparations

Standard Fittings & Location Criteria

Lists fittings and criteria for choosing an installation location.

Site Clearance & Communication Line Needs

Details site clearance requirements and communication line needs.

Electrical Wiring Requirements

Communication Line Specifications

Specifies communication cable types and power cord/switch capacity.

Indoor Unit Installation

Power Cords & Unit Dimensions

Guides on power cords and shows unit dimensions.

Suspending the Indoor Unit

Details drilling, bolts, and hanger bracket installation.

Ceiling Mounting & Refrigerant Piping

Covers ceiling considerations, pipe connection, and tightening.

Refrigerant Piping and Connection

Flaring Port & Nut Tightening

Guides on connecting the flaring port and tightening nuts with torque values.

Pipe Bending & Insulation

Advises on bending pipes correctly and insulating connection pipes with sponge.

Drainage System Installation

Drain Pipe Notices & Hose Installation

Rules for drain pipes and installing the drain hose.

Pipe Insulation & Connections

Covers pipe insulation, multiple connections, and trap installation.

Pipe Support & System Testing

Specifies pipe support and drainage system testing procedures.

Air Duct Installation

Duct Insulation, Clearance & Noise

Emphasizes duct insulation, clearance, and noise damping.

Duct Dimensions & Connections

Provides duct dimensions and shows air-out/return duct connections.

Return Air & Fresh Air Ducting

Covers bottom return air, fresh air pipes, and noise reduction.

Wired Controller Installation

Controller Installation Reference

Refers to a separate manual for controller installation.

Wiring Work

General Wiring Safety & Regulations

Emphasizes safety, regulations, and general wiring precautions.

Wiring Management & Terminal Connections

Covers wiring regulations and connecting wires to terminals.

Power Cord Connection

Power Cord & Circuit Breaker Requirements

Stresses circuit breakers and keeping units energized.

Power Cord Connection Steps

Outlines steps for connecting the power cord.

Indoor to Outdoor Unit Communication Wiring

Communication Cable Routing & Termination

Describes routing and terminating communication cables.

Wired Controller Communication Wiring

Bus Termination & Controller Connection

Covers bus termination and connecting controller wires.

Controller & Receiver Installation

Shows installation of wired controller and remote receiver.

Controller Network Configuration

Explains controller network setup and unit control limits.

External Static Pressure Setting

Adjustment Guide and Tables

Guides on setting pressure via controller/software with model-specific tables.

Routine Maintenance

Maintenance Safety Warnings

Provides critical warnings before cleaning, like turning off power.

Filter Cleaning & Pre-Season Checks

Details filter cleaning and pre-season maintenance checks.

Post-Season Maintenance & Error Codes

Advises post-season actions and lists indoor unit error codes.

Troubleshooting Common Issues

Startup, Operation & Performance Issues

Provides solutions for startup, operation, and performance problems.

Heating Fan & Cooling Issues

Explains heating fan behavior and troubleshooting cooling/heating effects.

Overview

This document serves as the Owner's Manual for Gree Commercial Air Conditioners, specifically focusing on Multi Variable Air Conditioners with Ducted Type Indoor Units. It provides essential information for installation, operation, and maintenance to ensure safe and correct usage of the product.

Function Description:

The device is a commercial air conditioner, part of Gree's Multi Variable Refrigerant Flow (VRF) system, designed for ducted indoor unit applications. Its primary function is to provide heating and cooling for commercial spaces, ensuring a comfortable indoor environment. The system allows for multiple indoor units to be connected to a single outdoor unit, offering flexibility and energy efficiency for various building layouts and demands. The ducted type indoor unit is designed for concealed ceiling installation, allowing for discreet integration into the building's aesthetics while delivering conditioned air through a ductwork system.

Important Technical Specifications:

The manual lists several models of ducted type indoor units, including:

  • GMV-ND22PHS/B-T
  • GMV-ND25PHS/B-T
  • GMV-ND28PHS/B-T
  • GMV-ND32PHS/B-T
  • GMV-ND36PHS/B-T
  • GMV-ND40PHS/B-T
  • GMV-ND45PHS/B-T
  • GMV-ND50PHS/B-T
  • GMV-ND56PHS/B-T
  • GMV-ND63PHS/B-T
  • GMV-ND71PHS/B-T
  • GMV-ND80PHS/B-T
  • GMV-ND90PHS/B-T
  • GMV-ND100PHS/B-T
  • GMV-ND112PHS/B-T
  • GMV-ND125PHS/B-T
  • GMV-ND140PHS/B-T
  • GMV-ND160PHS/B-T
  • GMV-ND180PHS/B-T

Rated Working Conditions:

  • Rated Cooling: Indoor Dry Bulb Temp 27°C, Wet Bulb Temp 19°C; Outdoor Dry Bulb Temp 35°C, Wet Bulb Temp 24°C.
  • Rated Heating: Indoor Dry Bulb Temp 20°C, Wet Bulb Temp 15°C; Outdoor Dry Bulb Temp 7°C, Wet Bulb Temp 6°C.

Communication Line Requirements:

  • For indoor unit and wired controller: Total length L (m) ≤ 250m, Wire size 2×0.75~2×1.25 mm², Material Standard IEC 60227-5. The cord should be circular with twisted cores. Shielded wire is recommended in environments with intense magnetic fields or strong interference.
  • For indoor unit and indoor (outdoor) unit: Total length L (m) ≤ 1000m, Wire size ≥ 2×0.75 mm², Material Standard IEC 60227-5. If wire diameter is enlarged to 2×1 mm², total communication line length can reach 1500m. Shielded wire is recommended in environments with intense magnetic fields or strong interference.

Power Cord Size and Air Switch Capacity:

For GMV-ND22~180PHS/B-T models:

  • Power Cord Size: 220~240V-1ph-50Hz or 208~230V-1ph-60Hz
  • Air Switch Capacity: 6A
  • Minimum Sectional Area of Ground Wire: 1.0 mm²
  • Minimum Sectional Area of Power Cord: 1.0 mm² Copper wire only should be used for power cords, with operating temperature within rated value. For power cords longer than 15m, the sectional area should be increased.

Installation Dimensions (Unit: mm):

Model A B C D E F G
GMV-ND22~50PHS/B-T 740 500 830 300 754 700 700
GMV-ND56~80PHS/B-T 1040 500 1130 300 754 1000 700
GMV-ND90~125PHS/B-T 1440 500 1530 300 754 1400 700
GMV-ND140~180PHS/B-T 1440 500 1580 300 754 1400 700

External Static Pressure:

Working range: 0 Pa to 200 Pa.

  • GMV-ND22~50PHS/B-T: Static pressure notch 2 (0 Pa) to 9 (150 Pa).
  • GMV-ND56~160PHS/B-T: Static pressure notch 2 (0 Pa) to 9 (200 Pa).
  • GMV-ND180PHS/B-T: Static pressure notch 2 (0 Pa) to 9 (170 Pa). Default static pressure notch for all models at ex-factory is 5.

Usage Features:

  • Concealed Installation: Designed as a concealed ceiling type unit, it integrates seamlessly into the interior design.
  • Wired Controller: The unit can be controlled via a wired controller. One wired controller can manage up to 16 indoor units. An indoor unit can also connect to two wired controllers (master and slave).
  • Remote Control Option: Users can purchase a remote controller and receiver separately for additional control convenience.
  • Preheating Function: Under standby status, the product consumes some power to maintain normal system communication and preheat refrigerant and lubricant. For long periods of non-use, power should be cut off. Before reusing, the unit should be energized and preheated in advance.
  • Safety Features: Includes various protection mechanisms such as indoor fan protection, E-heater protection, water full protection, freeze protection, power insufficiency protection, and overcurrent protection.
  • Error Code Display: The unit provides error codes for troubleshooting, covering issues like indoor unit error, sensor errors, communication errors, and module protection.

Maintenance Features:

  • Filter Cleaning: Filters should be removed from the inlet of the indoor unit and cleaned regularly (usually once every two weeks in dusty environments). Dust can be removed with a vacuum cleaner, or filters can be washed with warm water and mild detergent, then dried in the shade.
  • Seasonal Maintenance (Before Use):
    • Check for blockages at the air inlet and outlet of both indoor and outdoor units.
    • Verify secure grounding.
    • Ensure all power cords and communication cables are securely connected.
    • Check for any error codes after energizing.
  • Seasonal Maintenance (After Use):
    • Run the unit in fan mode for half a day on a sunny day to dry the inner parts.
    • For long periods of non-use, cut off the power supply to save energy.
  • Professional Service: Installation, movement, and maintenance should only be performed by designated dealers or qualified technicians. Users are advised not to disassemble or maintain the unit themselves to avoid damage, electric shock, or fire hazards.
  • Drainage System Testing: After electrical work, approximately 1L of purified water should be injected into the drain pan to test the drainage system, ensuring no leakage and proper operation of the water pump (if equipped). This test is strongly recommended before ceiling decoration.
  • Air Duct Maintenance: Insulating layers on air-out, air-return, and fresh air ducts should be maintained to prevent heat loss and moisture. Air duct junctions must be well-sealed to prevent air leakage. Filters should be added to the air-return opening.
  • Troubleshooting Guide: The manual includes a troubleshooting section to help identify common issues such as the unit not starting, stopping after a short run, poor cooling/heating effect, or the indoor fan not starting during heating. This guide helps users perform initial checks before contacting service.

Gree GMV-ND56PHS/B-T Specifications

General IconGeneral
BrandGree
ModelGMV-ND56PHS/B-T
CategoryAir Conditioner
LanguageEnglish