Loading...
Ceiling Assembly
ELECTRIC DIAGRAM
Roof Top Air Conditioner
- 2 -
Notice: Use Copper Conductors Only.
M1
STEPPING
MOTOR
M2
STEPPING
MOTOR
AP2
LED
BOARD
OUTDOOR UNIT
RT1
ROOM
SENSOR
AP1
DISPLAY
DISP1
SW1 SW2 CN1
DISP2
DISP3
BOARD
YEGN(GN)
BU(WH)
BN
L
N
POWER
PE
L
N
BU
YEGN
BN(BK)
TERMINAL
BLOCK
CAP.
WH
BU
BU
R
S
INDOOR UNIT
OUTROOM
SENSOR
YAW4 N
VALVE
4-WAY
4YV
MOTOR
DISP1
N1
COMP
PE
OUT_FAN
AC-L1
PE
BU
BN
YEGN
DISP2
AP1
YEGN
PE
ELECTRIC BOX
PE
YEGN
M3
PE
YEGN
OUT_FAN1
MOTOR
IN_FAN
PE
YEGN
IN_FAN
M1
OUTDOOR
TUBE SENSOR
CN5
RT1
TUBE
SENSOR
RT2
CN4
OUT_FAN
MAIN BOARD
RT3
M2
(20K) (15K)(20K)
(WH) (BK)
VT VT
K1
MOTOR
OUT_FAN
C
RD
COMP
YEGN
PE
COMP.