U-Match Series DC Inverter Service Manual 
30 
4.2 Low Temperature Drying Function 
Under dry mode and when set temperature is 16℃, continuously press ▼ button for twice and then 
the set temperature will be 12℃. In this case, the unit will enter low temperature drying function. 
When  low  temperature  drying  function  is  turned  on,  press  ▲  button  or  Mode  button  to  exit  low 
temperature drying function. 
4.3 Lock Function 
When unit is turned on normally or turned off, pressing ▲ and ▼ buttons at the same time for 5s will 
turn on Lock function. LCD will display . Pressing ▲ and ▼ buttons at the same time for 5s to turn off 
this function. 
When Lock function is turned on, any other buttons won‟t respond when pressing. The function can 
be memorized after power failure and then power recovery. 
4.4 Memory Function 
Press Mode and ▲ buttons at the same time for 5s under off state of the unit to turn on or cancel 
memory function. If memory function is set,    is displayed. If not, indoor unit is defaulted to be 
off after power recovery.   
If memory function is set, indoor unit will resume original setting state after power failure and then 
power recovery. 
Note:
 If cut off power with 5s after memorized content is changed, the memorized content may be 
abnormal. Do not cut off power within 5s after memorized content is changed. 
4.5 Door Control Function/Human Sensitive Function  
Door control function or human sensitive function can be selected (More details please refer to 
Debugging Function). These two functions can‟t be turned on at the same time. 
When door control function is selected, the wired controller will work when the room card is inserted 
and stop working when the room card is not inserted; when human sensitive function is selected, the 
wired controller will work when it senses there is somebody in the room and stop working when it senses 
there is nobody in the room. When the door control function senses the room card is not inserted or 
human sensitive function senses there is nobody in the room, the wired controller will display    icon. 
Note: 
⑤ 
In long-distance monitoring or centralized control, no matter the room card is inserted or not, the 
ON/OFF of unit can be controlled. If long-distance monitoring or centralized control information is 
received when the room card is not inserted,    icon is cleared. When the card is reinserted, 
door control function is judged to be turned on. If long-distance monitoring or centralized control 
information is received when the room card is inserted, it will keep the original status. 
⑥ 
The unit can not be controlled by buttons when the card is not inserted. 
⑦ 
When door control function and human sensitive function have been set at the same time, it is 
defaulted that door control function is valid and human sensitive function is invalid. 
4.6 Switch between Fahrenheit and Centigrade 
Under off state of the unit, press Mode and ▼ buttons at the same time for 5s to switch between 
Fahrenheit and Centigrade.