U-Match Series DC Inverter Service Manual 
34 
(4) Compensate 3℃ (LCD displays 03) 
(5) Compensate 4℃ (LCD displays 04) 
(6) Compensate 5℃ (LCD displays 05) 
(7) Compensate 6℃ (LCD displays 06) 
(8) Compensate 7℃ (LCD displays 07) 
(9) Compensate 8℃ (LCD displays 08) 
(10) Compensate 9℃ (LCD displays 09) 
(11) Compensate 10℃ (LCD displays 10) 
(12) Compensate 11℃ (LCD displays 11) 
(13) Compensate 12℃ (LCD displays 12) 
(14) Compensate 13℃ (LCD displays 13) 
(15) Compensate 14℃ (LCD displays 14) 
(16) Compensate 15℃ (LCD displays 15) 
Note:
 Indoor ambient temperature compensation can be set through wired controller (E.g. If 02 is 
selected; it indicates the compensation temperature is 2℃. If the indoor ambient temperature detected 
by  the  temperature  sensor  at  air  return  is  29℃,  the  ambient  temperature  after  compensation  is 
29℃-2℃=27℃).     
After  finishing  setting,  press  Enter/Cancel  button  to  save  and  exit  setting.  After  entering  this 
interface, the system will exit this menu if there is no operation on the button within 20s. Normal off state 
interface will be displayed and present setting will not be saved. 
5 INSTALLATION OF WIRED CONTROLLER 
5.1 Standard Accessories 
Table 2-5-1 Standard Accessories of Wired Controller