GREE DC INVERTER HEAT PUMP CONDENSING UNIT SERVICE MANUAL
82
Removal of Front Panel
NOTE: Before removing the front panel, make sure power is cut off.
Step Picture Work Instruction
4. Remove the handle and the
valve cover.
Unscrew the screws that
connect the handle to the
electric box, and unscrew
the screws that connect
the valve cover to the right
side plate.
5. Remove the right side plate.
Unscrew the screws that
connect the right side plate
to the electric box and the
screws around the right
side plate.
6. Install the right side plate.
Screw up the screws
around the right side plate.
Be careful to handle well
the clasps at the bottom of
the right side plate.