Removal of Fan and Motor
NOTE: Before removing the fan, make sure power is cut off.
Step Picture Work Instruction
1. Remove the grill.
Use a screwdriver to
unscrew the two screws
on the upper left and
lower right corners.
2. Remove the fan.
Use a wrench to remove
the specialized nut and
gasket of the fan.
NOTE: Please keep the
nut and gasket safe after
removing them from the
fan.
3. Remove motor.
Use a screwdriver to
unscrew the bolt of motor.
NOTE: Motor wire should
be first removed from the
electric box.