GREE DC INVERTER HEAT PUMP CONDENSING UNIT SERVICE MANUAL
96
Removal of Condenser
NOTE:Before removing the condenser, make sure there is no refrigerant in the pipeline and power is cut off.
Step Picture Work Instruction
5. Take out the condenser.
Loosen the securing screws
of condenser support. Take
off the plate type heat
exchanger and the support
as a whole.
6. Install the new
condenser.
Secure the screws of
condenser and support.
Then fix them together on
the chassis.