GREE U-Match 6 SERIES UNIT SERVICE MANUAL
118
Removal of compressor
Note: Before removing the compressor, make sure there is no refrigerant in the pipeline and power is cut off.
Step Picture Work instruction
6. Connect the compressor
suction port and exhause
port with the pipes.
Weld the compressor
connection pipes and
connect them to the
compressor.
Note: When replacing
the compressor, avoid
touching the nearby
pipeline and
components.
7. Connect the compressor
wires.
Connect the
compressor wires to the
wire terminals on the
top of compressor.
Note: When connecting
the wires, be sure to
match the colors with
the corresponding wire
terminals.
Model: GUD100W1/NhA-X,GUD125W1/NhA-X
Removal of 4-way valve
Note: Before removing the 4-way valve, make sure refrigerant is fully discharged from the unit and power is cut off.
Step Picture Work instruction
1. Take off the
electromagnetic coil of the
4-way valve.
Carefully unscrew the
screws of electromagnetic
coil with a screwdriver.