EasyManua.ls Logo

Gree GUHN48NM3A1O - Electric Wiring Work; Wiring Principle

Gree GUHN48NM3A1O
209 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
U-MATCH Air
Conditioners
Service Manual
6SHFL¿FDWLRQRI&RQQHFWLRQ3LSH
Model
External Diameter
Maximum Length
of Connection
Pipe
Maximum Difference
in Height between
Outdoor and Indoor
Unit
Additional Charge
of Refrigerant
Gas Pipe /LTXLG3LSH (m) (m) (g/m)
*8+11.$2
ĭ
3/8"
ĭ
1/4"  15 15
*8+11.$2
ĭ
1/2"
ĭ
1/4"  15 15
*8+11.$2
*8+11.$2
ĭ
5/8"
ĭ
3/8"  15 
*8+11.$2
*8+11.$2
ĭ
3/4"
ĭ
1/2"   
GUHN36NM3AO
GUHN42NM3AO
GUHN48NM3A1O
*8+110$2
*8+110$2
GUCN42NM3AO
ĭ
3/4"
ĭ
ij  25 
GUCN48NM3AO
(/(&75,&:,5,1*:25.
4.1 Wiring Principle
4.1.1 General

Perform wiring of the power supply in conformance with the regulations of the local electric company.

For the control wires connecting indoor units, and between indoor and outdoor units, use of double-core
shield wires is recommended to prevent noise trouble.

Be sure to set the earth leakage breaker and the switches to the power supply section of the indoor unit.

Supply power to each outdoor unit and provide an earth leakage breaker or hand switch for each outdoor
unit.

Store wiring system for control and refrigerant piping system in the same line.

Arrange the cables so that the electric wires do not come to contact with high-temperature part of the
refrigerant pipe; otherwise coating melts and an accident may be caused.

'RQRWWXUQRQSRZHURIWKHLQGRRUXQLWXQWLOYDFXXPLQJRIWKHUHIULJHUDQWSLSHZLOO¿QLVK

Installation should be conducted by National Wiring Regulation.

The rated voltage and exclusive power supply must be adopted for the air conditioners.

7KHSRZHUFDEOHVKRXOGEHUHOLDEOHDQG¿[HGLQRUGHUWRDYRLGWKHZLULQJWHUPLQDOEHVXIIHUHGIURPIRUFH
And do not drag the power cable forcibly.

The wire diameter of power cable should be large enough, if power cable and connection wire be
damaged, it should be replaced by the exclusive cable.

All electric installation must be done by professional personnel according to local law, regulation and this
manual.

It should be reliably earthed, and it should be connected to the special earth device, the installation work
should be operated by the professional.

The creepage protect switch and air switch must be installed.

Air switch should have the thermal dropout and magnetic dropout function, in order to avoid the short
circuit and overload.

The on spot connection should refer to the circuit diagram, which is stuck on the unit body.

7KHXQLWVKRXOGEHUHOLDEO\HDUWKLILWLVLPSURSHUO\HDUWKHGWKDWPD\FDXVHHOHFWULFVKRFNRU¿UH

Air conditioner is the “I” class electric appliance, thus please do conduct reliable grounding measure.

The yellow-green two-color wiring of air conditioner is grounding wire and cannot be used for other
SXUSRVHV,WFDQQRWEHFXWRIIDQGEH¿[HGE\VFUHZRWKHUZLVHLWZRXOGFDXVHHOHFWULFVKRFN

The user must offer the reliable grounding terminal. Please don’t connect the grounding wire to the
following places:
a. Water pipe;

Table of Contents