Gree GVH24AK-K3DNC6A - Indoor Unit Wiring Procedure

Gree GVH24AK-K3DNC6A
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
connecting cable
power cord
wire clamp
blue
yellow/green
wiring board
wire clamp
blue
black
(black)
brown
brown
3
Note:
Please contact the maintenance center for another connection wire with adequate
length if the present one is not long enough.
Correctly connect the wires.
Well screw up the screws fixing terminals and connection wirings.
The wirings should be properly fixed.
Incorrect wiring connection of grounding wire may lead to electric shock.
Well fix the electric box cover with sufficient screw. Improper assembly of electric
box cover may cause fire hazard or electric shock.
For the air conditioner without plug, an circuit break must be installed in the line.
The circuit break should be all-pole parting and the contact parting distance
should be more than 3mm.
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
Step two: Wiring of indoor unit
Installation of indoor unit
1.
Remove the left and right support plate.
electric box is in the left of the unit,
press the screw at the electric box cover,
2.
Take out the
electric box cover, screw down
the test wire of screw,take out the test wire
from the cable cross hole.
take off the electric box cover.
3. Thread the power connection wire thr-
ough the cable cross hole from the cable
cross hole.
4. Well connect the wire according to wi-
ring diagram. (see figure on the right)
5. Fix the protecting cover section of po-
wer connection wire at the groove of
wire clamp and then screw up the fix-
ing screw to fix the connection wire
firmly.
wiring board
test wire
cable cross hole
screw
37