38
Step three: Installation of rear cover
Installation of indoor unit
1. Bind the connection pipe, connection wire and drainage pipe together with
binder.
Fix some positions for convenient binding
Do not bind too tightly.
Leave the joint of connection pipe for leakage test.
Knock down the sub-small hole for 24 unit when cutting the baiting.
2. According to installation position, cut one of the baitings, thread the packed pipe
and wire through the baiting hole.
3. Assemble the rear case.
drainage
pipe
drainage
pipe
connection wire
binder
binder
connection pipe
connection
pipe
connection pipe,
connection wire and
drainage pipe
rear cover