HEALTH
  HEALTH
operation is defaulted). When indoor fan stops or turning of       function by remote controller,         function will be off.     
 
8. I Feel Function   
When the controller receives I Feel order, the controller will operate according to the ambient temperature. The remote controller will 
send ambient temperature to the controller every 10min. If the controller does not receive the ambient temperature sent by remote 
controller for 11min, the air conditioner will operate according the ambient temperature around it. If I Feel function is not set, the air 
conditioner will operate according the ambient temperature around it. This function is not memorized upon power failure.     
 
9. Reserved Fahrenheit Temperature   
The nixie tube will display the set temperature in Celsius temperature or Fahrenheit Temperature according to the order.  Setting 
range is 16~30ć  (61~86). In Auto mode, it will display 25ć  (77) during cooling and fan operation, and display 20ć  (68) 
during heating operation. For cooling only unit, it displays 25ć  (77).   
The indoor temperature displayed is sent by remote controller, ranging from 0~60ć  (32~99). If outdoor ambient temperature is 
received, the display remains the same. If valid control signal is received, it will display set temperature for 5s and then resume 
displaying ambient temperature.   
For units with memory function, set temperature will be displayed after re-energizing the unit.     
 
10. Cold Plasma Function   
Turning on the cold plasma function with remote controller when the fan operates, this function will act. Turning off the cold plasma 
function with remote controller or turning off the fan, this function will end.     
 
11. Turbo Function 
When the controller receives Turbo order, indoor fan runs in high speed, outdoor unit runs in high frequency in cooling mode and 
heating mode. 
13. Compulsory Defrosting Function
(1) Start up compulsory defrosting function
Under  ON  status,  set  heating  mode  with  remote controller  and  adjust the  temperature  to  16ºC.  Press “+,  -,  +,  -,  +,-”  button 
successively within 5s and the complete unit will enter into compulsory defrosting status. Meanwhile, heating indicator on indoor unit 
will ON 10s and OFF 0.5s successively. (Note: If complete unit  has malfunction or stops operation due to protection, compulsory 
defrosting function can be started up after malfunction or protection is resumed. 
(2)Exit compulsory defrosting mode
After compulsory defrosting is started up, the complete unit will exit defrosting operation according to the actual defrosting result, and 
the complete unit will resume normal heating operation. 
12. Comfortable and energy-saving function (this function is realized by setting energy-saving signal with remote controller. 
Please refer to corresponding part of remote controller in instruction manual)
①
Comfortable and energy-saving function is only valid under cooling mode. After setting is succeeded, set temperature of indoor unit 
is 27°C(81°F), and indoor unit displays “SE”. 
②
After setting is succeeded and compressor operates, fan speed is adjusted automatically according to below condition: 
When Tamb.≥32°C(90°F), indoor fan operates at super-high speed;
When 32°C(90°F),>Tamb.≥Tpreset
+
2°C(3~4°F),, indoor fan operates at high speed;
When Tpreset
<
Tamb
. <
Tpre
et +
2°C(3~4°F),, indoor fan operates at medium speed;
When Tamb.≤Tpreset, indoor fan operates at low speed. 
After setting is succeeded and compressor operates, the unit operates at low speed. 
③
There should be at least 3min and 30s operation time for the switchover among high speed, medium speed and low speed. 
④
After entering into energy-saving mode and When Tamb. ≥28°C(82°F),, horizontal louver operates at x-angle position 4. 10min 
later or Tamb. <28°C(82°F), or after receiving the changing order for swing angle, horizontal louver will operate the angle set by 
remote controller.  
⑤
Other requirement and protection is same as that under cooling mode. 
⑥
If set energy-saving function again under energy-saving mode, it will exit energy-saving mode.