25
Installation and Maintenance
Service Manual
NO. Items to be checked Possible malfunction
1
Has the unit been 
installed rmly?
The unit may drop, shake or 
emit noise.
2
Have you done the 
refrigerant leakage test?
It may cause insufcient cooling 
(heating) capacity.
3
Is heat insulation of 
pipeline sufcient?
It may cause condensation and 
water dripping.
4 Is water drained well?
It may cause condensation and 
water dripping.
5
Is the voltage of power 
supply according to the 
voltage marked on the 
nameplate?
It may cause malfunction or 
damage the parts.
6
Is electric wiring and 
pipeline installed 
correctly?
It may cause malfunction or 
damage the parts.
7
Is the unit grounded 
securely?
It may cause electric leakage.
8
Does the power cord 
follow the specication?
It may cause malfunction or 
damage the parts.
9
Is there any obstruction 
in air inlet and air outlet?
It may cause insufcient cooling 
(heating).
10
The dust and 
sundries caused 
during installation are 
removed?
It may cause malfunction or 
damaging the parts.
11
The gas valve and liquid 
valve of connection pipe 
are open completely?
It may cause insufcient cooling 
(heating) capacity.
1. Check after Installation
Check  according  to  the  following  requirement  after  finishing 
installation.
2. Test Operation
(1) Preparation of test operation
● The client approves the air conditioner installation.
● Specify the important notes for air conditioner to the client.
(2) Method of test operation
● Put through the power, press ON/OFF  button  on the remote 
controller to start operation.
● Press MODE button to select AUTO, COOL, DRY,  FAN and 
HEAT to check whether the operation is normal or not.
● If the ambient temperature is lower than 16
℃
, the air 
conditioner can’t start cooling.
7.6 Check  after  Installation and Test 
Operation