Installation and Maintenance
Service Manual
7. Notes for Installation and Maintenance
Safety Precautions: Important!
Please read the safety precautions  carefully  before  installa-
tion and maintenance.
The following  contents  are very  important  for installation 
and maintenance.
Please follow the instructions below.
●  The  installation  or  maintenance  must  accord  with  the  in-
structions.
● Comply with all national electrical codes and local electri-
cal codes.
● Pay attention to the warnings and cautions in this manual.
● All installation and maintenance shall be performed by dis-
tributor or qualied person.
● All  electric  work  must  be  performed  by  a  licensed  tech-
nician  according  to local  regulations  and  the  instructions 
given in this manual.
●  Be  caution  during  installation and  maintenance.  Prohibit 
incorrect  operation  to  prevent  electric  shock,  casualty  and 
other accidents.
 
WARNINGS
Electrical Safety Precautions:
1. Cut off the power supply of air conditioner before check-
ing and maintenance.
2.  The  air condition  must  apply  specialized  circuit and  pro-
hibit share the same circuit with other appliances.
3. The air conditioner should be installed in suitable location 
and ensure the power plug is touchable.
4. Make sure each wiring terminal is connected rmly during 
installation and maintenance.
5. Have the unit adequately grounded. The grounding wire 
can't be used for other purposes.
6.  Must apply  protective  accessories  such as  protective 
boards, cable-cross loop and wire clip.
7.  The  live  wire,  neutral  wire  and  grounding  wire  of  power 
supply must be corresponding  to  the  live wire, neutral wire 
and grounding wire of the air conditioner.  
8.  The power  cord  and power  connection  wires can't  be 
pressed by hard objects.
9. If power cord or connection wire is broken, it must be re-
placed by a qualied person.
10. If the power cord or connection wire is not long enough, 
please  get  the specialized  power  cord  or  connection wire 
from the  manufacture  or  distributor.  Prohibit  prolong the 
wire by yourself.
11.  For  the air  conditioner  without  plug,  an air  switch  must 
be  installed  in  the  circuit.  The  air  switch should  be all-pole 
parting  and  the  contact  parting  distance  should  be  more 
than 3mm.
12. Make  sure  all wires  and  pipes are  connected  properly 
and the valves are opened before energizing.
13. Check if there is electric leakage on the unit body. If yes, 
please eliminate the electric leakage.
14. Replace  the  fuse with a  new  one of the  same  specica-
tion if it is burnt down; Don't replace it with a cooper wire or 
conducting wire.
15. If the unit  is to be installed in a humid  place, the circuit 
breaker must be installed.
Installation Safety Precautions:
1.  Select  the  installation  location  according  to  the  require-
ment of  this  manual.(See  the  requirements  in installation 
part)
2.  Handle  unit  transportation with  care;  the  unit  should  not 
be carried by only one person if it is more than 20kg.
3. When  installing  the indoor unit  and  outdoor unit,  a  suf-
cient xing bolt must be installed; make sure the installation 
support is rm.
4. Ware safety belt if the height of working is above 2m.
5. Use equipped components or appointed components dur-
ing installation.
6. Make sure no  foreign objects are left in the  unit after n-
ishing installation.
Refrigerant Safety Precautions:
1. When refrigerant leaks or requires discharge during instal-
lation, maintenance, or disassembly, it should be handled by 
certied professionals or otherwise in compliance with local 
laws and regulations.
2. Avoid contact between refrigerant and re as it generates 
poisonous  gas;  Prohibit  prolong  the  connection pipe by 
welding.
3. Apply specied refrigerant only. Never have it mixed with 
any other refrigerant. Never have air remain in the refrigerant 
line as it may lead to rupture or other hazards.
4. Make sure no refrigerant gas is leaking out when installa-
tion is completed.
5. If there is refrigerant leakage, please take sufcient mea-
sure to minimize the density of refrigerant.
6. Never touch the refrigerant piping or compressor without 
wearing glove to avoid scald or frostbite.
Improper installation may lead to re hazard, explosion, 
electric shock or injury.