11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Step Procedure
1.Remove lter
a Open the panel.
b
Loosen the clasp shown in the g and then pull the left
lter and right ler outwards to remove them.
2.Remove horizontal louver
Push out the axile bush on horizontal louver. Bend
the horizontal louver with hand and then separate the
horizontal louver from the crankshaft of step motor to
remove it.
Location of step motor
Axile bush
Panel
Clasps
Left lter and right ler
Horizontal louver
07/09/12K