Function and Control
4. Other Controls
(1) ON/OFF
Press the remote button ON/OFF: the on-off state will be changed once each time you press the button.
(2) Mode Selection:
Press the remote button MODE, then select and show in the following ways: AUTO, COOL, DRY, FAN, HEAT, AUTO.
(3) Temperature Setting Option Button
Each time you press the remote button TEMP+ or TEMP-, the setting temperature will be up or down by 1.8 . Regulating
Range: 61~86 , the button is useless under the AUTO mode.
(4) Time Switch
You should start and stop the machine according to the setting time by remote control.
(5) SLEEP State Control
a. When the air conditioner is under the mode of COOL, DRY, and the SLEEP mode has been set well, after the SLEEP state
keeps about 1 hour, the pre-setting T will raise 1.8 , and it will raise 1.8 again after 2 hours, so it raise 3.6 in 2 hours,
then it will run on at the setting temperature and wind speed.
b. When the air conditioner is under the mode of HEAT, and the Timer has been set well, after the SLEEP state keeps about 1
hour, the pre-setting T will reduce 1.8 , and it will reduce 1.8 again after 2 hours, so it reduce 3.6 in 2 hours, then it will
run on at the setting temperature and wind speed.
c. The setting temperature keeps the same under the FAN mode and AUTO mode.
(6) Indoor Fan Control
The Indoor Fan can be set as HIGH, MED, LOW by remote control, and the Indoor Fan will be respectively run at high, medium, low
speed. It will also be set as AUTO, and the Indoor Fan is as the followings at the automatic wind speed.
Cooling mode: T
ring T setting + 3.6, high speed; T setting - 3.6<T ring<T setting + 3.6, medium speed; T ring T setting - 3.6, low speed.
Sending wind mode: : T
ring > T setting+ 7.2, high speed; T setting +3.6 T ring T setting + 7.2, medium speed; T ring<T setting +3.6, low
speed. Moisture removal mode: force to be set as the low speed
Heating mode: T
ring T setting + 1.8 high speed; T setting +1.8<T ring<T setting + 9, medium speed; T ring T setting + 3.6, low speed.
(7) Buzzer Control
The buzzer will send a
sound when the air conditioner is powered up or received the information sent by the remote
control or there is a button input, the single tube cooler doesn
t receive the remote control ON signal under the mode of heating
mode.
(8) Auto button
If the controller is on, it will stop by pressing the button, and if the controller is off, it will be automatic running state by pressing the
button, swing on and light on, and the main unit will run based on the remote control if there is remote control order.
(9) Up-and-Down Swinging Control
When power on, the up-and-down motor will firstly move the air deflector to o counter-clockwise, close the air outlet. After starting
the machine, if you don
t set the swinging function, heating mode and auto-heating mode, the up-and-down air deflector will
move to D clockwise; under other modes, the up-and-down air deflector will move to L1. If you set the swinging function when you
start the machine, then the wind blade will swing between L and D. The air deflector has 7 swinging states: Location L, Location
A, Location B, Location C, Location D, Location L to Location D, stop at any location between L-D (the included angle between L~D
is the same). The air deflector will be closed at 0 Location, and the swinging is effectual only on condition that setting the swinging
order and the inner fan is running. The indoor fan and compressor may get the power when air deflector is on the default location.
Designation of sensors Faults
Indoor ambient temperature
The sensor is detected to be open-circuited or short-circuited for
successive 20 seconds
Indoor tube temperature
The sensor is detected to be open-circuited or short-circuited for
successive 20 seconds
Outdoor ambient temperature
The sensor is detected to be open-circuited or short-circuited for
successive 30 seconds
Outdoor tube temperature
The sensor is detected to be open-circuited or short-circuited for
successive 30 seconds, and no detection is performed within 10 minutes
after defrost begins.
Exhaust
After the compressor has operated for 3 minutes, the sensor is detected
to be open-circuited or short-circuited for successive 30 seconds.
Overload
After the compressor has operated for 3 minutes, the sensor is detected
to be open-circuited or short-circuited for successive 30 seconds.
ºF
ºF
ºF
ºF
ºF
ºF
ºFºF
21